
tm2692 Jan-20
18
2.6. Display notifications
During normal machine operation different notifications may be displayed on the
screen. Below is the list and operator’s actions suggested to be taken.
Heating / Popping / Pause / Cooling
Indicates current operation mode.
Load corn in left (right) hopper
Corn sensor has been tripped. Refill the hopper or let the machine to process
kernels left. See also “Corn Sensor Delay” setting.
Change bag with popcorn
Bag sensor is tripped. Replace the full cart. Failing to do so will lead to sound
alarm activation and machine will automatically go in pause mode shortly.
Oil and salt will start automatically
While Butterfly program in operation, this message will appear once corn
kernels started to be supplied in the chamber. This is just a reminder that oil
and salt supply will start in certain time. See “Oil Turn On Delay” setting.
Chamber is clogged with popcorn
Machine chamber is equipped with chamber clogging sensor that watches what
is happening in the chamber. Based on the sensor’s output, machine can
increase turbine spinning rate automatically in order to blow out excessive stuff
out of the chamber. If it is not sufficient, then sensor trips and machine switches
into cooling mode, and said message can be seen on the screen.
Chamber clogging sensor trips not only in case of actual clogging, but also in
case if too small amount of corn was put in the hopper or corn sensors have
been blinded (for purpose or incidentally). To continue operation, related
indicator should be released. See “Overload” indicator in section 2.4.
Automatic machine disconnection
Machine has been forcedly switched into cooling mode. Use an observation port
Summary of Contents for ROBOPOP 60
Page 34: ...tm2692 Jan 20 34 Annex F Parts list ...
Page 35: ...tm2692 Jan 20 35 ...