3.0 TECHNICAL DATA
The Riviera R.S. and Belvedere R.S. heaters are room sealed, inset live fuel effect gas heaters with coals.
The heater can be mounted only on a non-combustible hearth, and can be fitted into a suitable fire surround(rated at
o
150 C). The heater can be installed on a normal brick wall from the inside of a building making it ideal for rooms where
access from the outside is difficult, for example multi-storey buildings. If the heater is to be installed on a combustible
wall, then the combustible wall kit, Part No. 994530, must be used together with a 152 mm rebated surround.
Four flues are available:
RW Part No.
Mini (telescopic)flue for walls from 280mm to 353mm
990177
Short (requires cutting)flue for walls from 225mm to 353mm
993241
Medium (telescopic) flue for walls from 353mm to 507mm
993240
Long (telescopic) flue for walls from 507mm to 658mm
993239
The heater is for use on Natural Gas only (G20 at 20 mbar supply pressure).
The appliance data badge is located on the LH side of the base panel.
The following optional extras are available: -
RW Part No.
Combustible Wall Kit
994530
Terminal Guard
994371
Gas Safety (Installation and Use) Regulations).
It is the law that all gas appliances are installed by competent persons in accordance with technical requirements.
The following items relate to this appliance:
1. BS 5871
2. BS 5440
3. BS 6891
4. The Building Regulations issued by the Department of Environment and the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
5. Any other relevant British Standard Code of Practice and/or Local Building Regulations.
6. Installation must comply with these instructions and be in accordance with the rules in force.
1.0 DESCRIPTION
2.0 INSTALLATION REQUIREMENTS
Height
595 mm
Width
495 mm
Depth(rearwards projection)
144 mm
Weight
14.5 Kg (43lbs)
Gas Type
Natural Gas
Max. Heat Input (gross)
3.8 kW
Efficiency
Class 1
Max.Heat Output
2.8kW
Min Heat Input (Econ)
2.0kW
Min Heat Output
1.5kW
Height to Centre Line of Flue
427 mm
Setting Pressure
COLD 17.0mbar ± 1.0 mbar
Supply Pressure
20 mbar
Burner
RW Part No. 989236
Injector
Bray Cat 16/250
Pilot Burner
RW Part No. 822367
Ignition
Piezo spark ignition operated as control tap is turned.
Control Tap / FSD
Concentric TESA 2377/A8
Spark Gap
3 to 4 mm
Control Knob Settings
OFF, PILOT / IGNITION , HIGH, MED, LOW, ECON
Gas Connection
8mm Tube nut & olive into Isolating Elbow (supplied)
4