SERVICE & INSTALLATION

Installation and Servicing Instructions

Room Sealed Live Fuel Effect Gas Fire

PRODUCT No. A99003 (BLACK)   A99004 (BRONZE)

‘CE MARKED’ FOR USE IN G.B. & I.E.

LEAVE THESE INSTRUCTIONS WITH THE USER

FIRECHARM R.S. LPG

Summary of Contents for A99003

Page 1: ...STALLATION Installation and Servicing Instructions Room Sealed Live Fuel Effect Gas Fire PRODUCT No A99003 BLACK A99004 BRONZE CE MARKED FOR USE IN G B I E LEAVE THESE INSTRUCTIONS WITH THE USER FIREC...

Page 2: ...ross Max Heat Output 3 53kW Min Heat Output 1 55kW Height to Centre Line of Flue 351mm Setting Pressure Cold 36 0mbar 1mbar 14 4in w g 0 4in w g Supply Pressure 37 0mbar 14 8in w g Burner Main Bray Ae...

Page 3: ...combustible wall such that the bottom of the backplate of the fire is at least 60mm above the finished floor level NOTE Soft wall coverings e g blown vinyl wallpaper may become discoloured if close to...

Page 4: ...nies or car port roof 600mm E From vertical soil pipes or drain pipes 75mm F From internal or external corners 600mm G Above ground roof or balcony level 300mm H From a surface facing a terminal 600mm...

Page 5: ...e the fire can be installed as directed in The Institute of Gas Engineers Utilization Procedure IGE UP 7 GAS INSTALLATIONS IN TIMBER FRAME BUILDINGS 3 The combustible wall kit is suitable for walls in...

Page 6: ...ted to the fire The flanges of the ducts are marked TOP to indicate the way in which the ducts are to be fitted Note do not remove the two middle slotted screws NOTE The flue and air ducts do not need...

Page 7: ...ixing holes to go over them Offer the fire with the flue through the wall and hook the keyholes over the screws Insert the lower wall fixing screws and secure all four screws g If a terminal guard is...

Page 8: ...fire should be serviced annually by British Gas or a CORGI registered service agent d When the fire is first lit a slight smell may be noticed but this will quickly clear away with use Hand over the...

Page 9: ...1 above access to the injectors is achieved by first removing the respective injector feed pipe then withdrawing the injector Only withdraw one injector at a time The upper injector is size 180 and fe...

Page 10: ...D Mill Lane Old Swan Liverpool L13 4AJ Telephone 0151 228 9111 Fax 0151 228 6661 MAKERS NUMBER DESCRIPTION 991328 Coal Bed 991967 Control Knob 822197 Gas Tap 820363 Spark Electrode 822131 Pilot Filter...