2.0 UNPACKING
3.0 SITING GENERAL
The fire is packed in a carton together with the following items (See Fig. 1):-
1. Medium flue assembly and sealing tape.
2. Gasket pack comprising flue and air duct gaskets and sealing gasket.
3. Flue sealing plate.
4. Pack of fittings comprising: 4 Wall fixing screws (2in wood)
810500
4 Wall plugs
820813
1 Spindle washer
810835
3 M4 x 10 Taptite screws (air duct)
810327
2 No. 6 S/T x 10 posi pan
810776
5. Foam seal pack. 822092.
6. A template representing the backplate full size; indicating the positions of the air inlet duct and fixing screw positions.
7. The fuel effect.
Remove the items and keep in a safe place. Lay the fire on its back in a safe place.
The fire must be mounted on the inner face of a suitable external wall of thickness 75mm minimum and 508mm maximum.
(a) HEARTH MOUNTING: If the fire is to be hearth mounted, the hearth must be of non-combustible material at least
13mm thick and measuring at least 670mm wide by 300mm deep with the fire central. Its top surface should preferably
be 50mm above the floor level to discourage placing of rugs or carpets over it.
(b) WALL MOUNTING: The fire may be fitted on a non-combustible wall such that the bottom of the backplate of the fire is
at least 60mm above the finished floor level.
NOTE: Soft wall coverings e.g. blown vinyl wallpaper may become discoloured if close to a heating appliance. Please
bear this in mind when installing this fire and when redecorating.
(c) FITTING IN A FIRE SURROUND (Fig. 2): The fire can be fitted in a compatible fire surround having a standard gas fire
cut-out or with a hole 135mm diameter to accept the flue. The material of the surround must be suitable for 100°C
application i.e. marked with the suffix ‘100’.
The inside of the external wall should be sealed off to prevent draught from the cavity into the room. A foam seal pack
is provided for this purpose. Wrap some of the foam seal around the inner air duct so that when the fire is installed, the
foam seal expands to prevent draught into the room.
NOTES;
1. The foam seal starts to expand once the compression tape is removed. Hence the foam seal should be put on only
when the fire is ready to be installed.
2. When fixing the flue length, the wall thickness must be measured from the inner face of the fire surround (Refer to
Section 5.2).