Pre-Installation
Ducting
The method of ducting should be carefully considered before installing the rangehood. 150mm round ducting should be
used in conjunction with this model rangehood. Alternatively, this rangehood can be operated in recirculation mode.
Installation Position
A.
Vertical height from bottom of Rangehood to Fixing Plate mounting screws:
302mm.
B.
Set height from the hob surface to the underside face of the rangehood at
750mm
for electric hob or gas hob.
Please check that the length of your chimney assembly will reach your ceiling before securing the
rangehood to the wall.
Be advised that the chimney height is such that the optimum height for installation is 750mm above the
hob. Should you wish to have the unit lower, or you have a ceiling higher than the typical 2.4 meter (8
foot), and then please choose the desired chimney extension kit.
Minimum
height from the hob surface to the underside face of the rangehood:
650mm
‐
chimney extension kit required.
Notes
: If the instructions for the gas hob specify a greater distance, this has to be taken into account. Any
installation above 750mm will compromise the performance.
C.
Distance between mounting screw holes on Fixing Plate:
115mm.