background image

 

 

Cleaning and Maintenance 

General Maintenance 

Switch off the rangehood before cleaning or maintenance. 

 To prevent surface damage never use abrasive or oil based liquid cleaners. To clean the surfaces of the 

appliance, use mild detergent and warm water. In areas of high humidity and coastal environments 

cleaning should be carried out frequently. 

 

Warning

: A buildup of oil may occur if the compact canopy is not cleaned regularly. 

Filter Maintenance 

To maintain efficiency, the filters should be removed regularly (approximately monthly), and washed using hot soapy 

water or the dishwasher. 

 Some discolouration of the filter frame may occur if washed in the dishwasher. 

Rangehoods fitted with charcoal filters are designed to remove grease and odours from cooking vapours prior to the 

cleansed air re‐entering the kitchen (when the rangehood is in recirculation mode). Charcoal filters should be replaced 

every two to four months depending on use. 

 Fully saturated charcoal filters can become a barrier to air movement therefore limiting rangehood 

performance. In the event of fire, grease laden filters could be flammable and therefore regular 

replacement is recommended. In ducted installations, conventional aluminium filters are recommended. 

Replacement of LED Lamps 

The LED lamps cannot be replaced by the consumer. If any faults occur, please call your nearest Service Department. 

Replacement parts 

Charcoal filter 

RPD6CF152 (RPD3CL6WH, RPD3CL6BK) 

RPD7CF152 (RPD3CL7WH, RPD3CL7BK) 

RPD9CF152 (RPD3CL9WH, RPD3CL9BK) 

For any other problems please call help line on NZ 0800 760 667 or AUS 1800 648 556 

 

 

Summary of Contents for RPD3CL6BK

Page 1: ...Installation and Operating Instructions Model Numbers RPD3CL6BK RPD3CL6WH RPD3CL7BK RPD3CL7WH RPD3CL9BK RPD3CL9WH Description Under mount Rangehood Pictured RPD3CL7BK ...

Page 2: ...of of purchase along with any other important documents about this product for future reference Due to continual product development Robinhood reserves the right to alter specifications or appearances without notice Important Safety Instructions 1 Appliance Details 2 Pre Installation 3 Installation 4 Operating Instructions 5 Cleaning and Maintenance 6 Troubleshooting 7 Warranty Certificate New Zea...

Page 3: ...oking 13 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours 14 Turn off the range hood when not in use 15 Do not use the range hood if it is damaged especially the supply cord and the case 16 Do not immerse the range hood in liquid 17 The exhaust air must not be discharged into a flue which i...

Page 4: ...et accessible for further consultations The appliance has been designed to exhaust cooking fumes externally Before installation please ensure that the following have been supplied and that the tools listed below are readily available Contents of packaging 1 x Rangehood 1 x Ø150mm outlet adaptor 4 x ST4x8mm screws Typical equipment required Electric drill Screwdriver Tape measure Spirit level Duct ...

Page 5: ...uctural material in the run e g rafters Please note that this chart is designed as a guide Please consult Robinhood customer services if unsure For NZ phone 09 415 6000 or www robinhood co nz For AUS phone 1800 648 556 or www robinhood com au Before drilling any holes check that the area behind the surface to be drilled is clear of any electrical cables pipes etc The cabinet must take a weight bea...

Page 6: ...M4x45mm bracket screws see diagrams below until the rangehood is fully secured in the cabinet Fix the bottom fascia panel back to the rangehood using the original M4x10mm screws Cut a ventilation flue hole in the cupboard size and position will depend on the ducting method chosen RPD3CL6WH RPD3CL6BK RPD3CL7WH RPD3CL7BK RPD3CL9WH RPD3CL9BK Warning Failure to install the screws or fixing devices in ...

Page 7: ...ress a second time and they will turn off Fan speed The exhaust fan is operated by the three fan speed buttons Pressing the button once will turn on the fan low medium and high speeds and pressing a second time will turn the fan off Timer When the exhaust fan is in use pressing the Timer button will set up a 5 minute delay after which the appliance will return to stand by mode NOTE if the lights a...

Page 8: ...rcoal filters are designed to remove grease and odours from cooking vapours prior to the cleansed air re entering the kitchen when the rangehood is in recirculation mode Charcoal filters should be replaced every two to four months depending on use Fully saturated charcoal filters can become a barrier to air movement therefore limiting rangehood performance In the event of fire grease laden filters...

Page 9: ...ge Power wire cut off Change power wire Switch damage Contact Service Department Appliance vibrates violently Motor screw loosen Contact Service Department Fixing brackets loose Tighten the fixing brackets Insufficient suction The distance between the body and the cooktop too long Readjust the distance Cross ventilation too strong or too closed in the kitchen Reduce cross ventilation or open the w...

Page 10: ... products such as abrasive cream or powder cleansers furniture polish bleach mentholated spirits drain cleaners sugar soap metal pads and strongly alkaline or acidic cleaners Heat damage including from washing the product at high temperatures Impact or mishandling the product including the impact caused by objects scraped along thrown or dropped on the product surface or excessive weight being pla...

Page 11: ...hood com au www robinhood com au Attention Customer Services Manager Warranty exclusions 1 The warranty does not apply where in Shriro s opinion The defect is caused by misuse wear and tear dirt fire or accidental damage The product has been repaired or serviced by an unauthorised person The product was not installed in accordance with our instructions The product was purchased overseas or was not...

Reviews: