6
Installation
Before drilling any holes check that the area behind the surface to be drilled is clear of any
electrical cables, pipes etc. The cabinet must take a weight bearing of at least 40kgs weight
.
Whenever possible protect the Rangehood with a fabric sheet or similar.
WARNING: Failure to install the screws or fixing devices in accordance with these instructions
may result in an electrical hazard
.
The power plug shall be accessible for disconnection of the
appliance after installation.
Mounting of the V-flap
If the cooker hood does not have an assembled V-flap 1, you should mount the half-parts to its body. The images
only show an example of how to mount the V-flap, the outlet may be various according to different models and
configuration.
To mount the V-flap 1 you should:
•
Mount two half-parts 2 into the body 6;
•
A pin 3 should be top oriented;
•
The axis 4 should be inserted in the holes 5 on body;
•
Repeat all the operations for the 2nd half-part.
Installation
•
Before installation, turn the unit off and unplug it from the outlet;
•
The rangehood should be placed at a distance of 65-75cm from the cooking surface for best effect;
•
The ceiling must can bear at least 120kgs weight, and the thickness of the ceiling must be
≧
30MM, drill
1*170mm round hole in the ceiling;