5-4-19 STOP SWITCH
(1) Install stop switch to blower housing.
(2) Connect wires referring to the wiring diagram.
- End of the reassembly -
5-4-18 BLOWER HOUSING AND RECOIL STARTER
(1) Attach blower housing to crankcase. Tighten
five flange bolts.
M6 x 12 mm flange bolt : 5 pcs.
Insert the high tension cord from the ignition
coil into the notch of the blower housing so as
not to pinch the cord.
(2) Install recoil starter to blower housing.
M6 x 8 mm flange bolt : 4 pcs.
Note:
Be careful of pulling direction of starter
rope.
Fig. 5-42
Model: EH12-2D
CLAMP
STOP SWITCH WIRE
STOP SWITCH