After pressing “B”, should “ERROR” appear in the upper row, followed by five (5) beeps, you have 
exceeded  the timer’s measuring capability of 1000 mph/kph.  When this occurs, the Lap Time continues to 
run.  To correct the error, simply press “C” to return to the previously recorded lap.  Then press “B” to take 
the appropriate lap readings. 
 
Upon completion of the event, or to stop the Speed Timer at any time, press “A”.  “STOP” indicator 
appears and one (1) is added to the Lap Counter. 
 
Then, press “B” once, to display the accumulated time and again to reset to all zeros. 
 

AVERAGE, MAXIMUM and MEMORY Functions 
 

The MAXIMUM SPEED/FASTEST LAP reading can be displayed at any time, by pressing “D”.  The 
“MAX” indicator will appear, as will the lap number, speed and time of the fastest lap.  To return to any 
previous function, press “C” or the SC-554 will automatically do so after 15 seconds. 
 
The AVERAGE SPEED and TIME of multiple laps, up to 999, can be computed and displayed at any time, 
by pressing “D”, again.  “AVG” indicator appears and the average lap time will appear in the upper row of 
the display, along with the total number of laps completed. 
 
30 MEMORY RECALL of lap speed, time and number can be displayed at any time, up through 999 laps, 
by pressing “F”.  Recall “RCL” indicator appears.  Holding “F” down, will cause the previous readings to 
be displayed at a rate of one per second. 
 
If the “RUN” indicator appears, you may take another Speed reading at any time, by pressing “B”.  You 
may also instantly return to the last previous reading at any time by pressing “C”. 
 
The memory recall operation will review previous readings in ascending “UP” or descending “DN” order, 
depending on the option selected. 
 
NOTES: 
(1)

 

The SPEED TIMER will not operate unless a distance has been entered. 

(2)

 

The SC-554 will measure up to 24 hours or 999 laps. 

 

 

LIMITED WARRANTY

 

OUR BASIC POLICY

 

Marshall-Browning International Corporation (MBI Corp.) warrants to the original owner, this quartz digital liquid display timepiece 
(excluding battery, lens, band, or strap) for the period of one year from the original purchase date.  This limited warranty is given by 
MBI Corp. and not by the dealer from whom the timepiece was purchased. 
 

THE WARRANTY PROCESS - WHAT IS COVERED BY THE WARRANTY

  

If the timepiece develops a manufacturing defect within the one-year limited warranty period, it will be either repaired or replaced (at 
MBI Corp.'s option) with a timepiece of equal or greater value, providing the original owner submits the following: 
1. 

Proof of purchase, i.e. a validated store receipt showing date of purchase. 

2. 

A check or money order (no cash, please) in the amount of $6.50 to cover the cost of 

shipping and handling. 

WHAT IS NOT COVERED BY THE WARRANTY

 

A. 

MBI Corp. will 

not 

repair defects or damages caused by or showing evidence of: 

1. 

Improper or unauthorized service. 

2. 

Misuse, tampering, abuse, or mistreatment of the timepiece. 

3. 

Damage to the case or visible cracking of the lens. 

4. 

Moisture damage, if the product is a non-water-resistant timepiece. 

B. 

If we find that the battery is the cause of the defect, MBI Corp. reserves the right to charge you ($6.50) for a new 

replacement. 
 
MBI Corp. is not liable for incidental or consequential damages.  Some states do not allow the exclusion or limitation of incidental or 
consequential damages, so the above limitation may not apply to you. 

YOUR RIGHTS UNDER IMPLIED WARRANTIES AND STATE LAW.

 

MBI Corp. limits the duration of any warranty implied by state law, including the implied warranty of merchantability, to one year 
from the date of original purchase.  Some states do not allow limitations on how long an implied warranty lasts, so the above 

Summary of Contents for SC-554

Page 1: ...s activated by pressing a pushbutton Once you are familiar with the SC 554 s operation you will be ready to enjoy its many functions The starting point for any operation is the NORMAL TIME mode You ma...

Page 2: ...up to Previous 30 Laps in Ascending up or Descending down Order Automatic Lap Counter up to 999 Laps Enter Distance Precise to 1 1000 Mile or Kilometer 1 100 Second Resolution up to 24 Hours Automatic...

Page 3: ...s C to arm or disarm your alarm and chime The sequence is 1 Alarm ON Chime OFF 2 Chime ON Alarm OFF 3 Alarm ON Chime ON 4 Alarm OFF Chime OFF When armed the alarm will sound when the Alarm Time coinci...

Page 4: ...le using the memory You may also return to the last previous reading at any time by pressing C AVERAGE LAP TIME MAXIMUM FASTEST LAP TIME The Average and Fastest Lap Times can be displayed at any time...

Page 5: ...frozen in the upper and lower rows of the display You may press E to release the frozen display to the current running LAP and SPLIT times or the SC 554 will automatically do so after 15 seconds Upon...

Page 6: ...t are Water Ski Slalom Course 850 feet 0 161 mile Pitcher s Mound Baseball 60 5 feet 0 011 mile Pitcher s Mound Youth 47 feet 0 009 mile Pitcher s Mound Softball 45 47 feet 009 mile Convert meters to...

Page 7: ...r is in the reset position The recall direction cannot be selected while the Speed Timer is running or not in the reset position 1 For Single Lap Events Press A to start RUN indicator appears Press A...

Page 8: ...perate unless a distance has been entered 2 The SC 554 will measure up to 24 hours or 999 laps LIMITED WARRANTY OUR BASIC POLICY Marshall Browning International Corporation MBI Corp warrants to the or...

Page 9: ...er resistant avoid immersing or exposing it to water steam or other forms of moisture WHEN YOU REQUIRE SERVICE If your timepiece ever requires factory servicing you can send it directly to MBI Corp 11...