background image

Page x of y 
Rev 02 05/04/05 

Stroke Rate Calculation 

You may calculate stroke rate based on one, two or three stroke cycles.  Since we are not interested in 
MPH/KPH, we will disregard those indicators. 
 
Following the instructions in the “Enter Distance” section, please enter the following values for their 
respective stroke cycles: 
 
 

One (1) stroke cycle  . . . please enter 0.017 

 

Two (2) stroke cycles . . . please enter 0.034 

 

Three (3) stroke cycles . . . please enter 0.050 

 
To measure stroke rate, simply START the timer by pressing “A” at the beginning of the cycle and STOP 
the timer by pressing “A” again at the completion of the cycle.  The number displayed in the upper row of 
the display is the 

Stroke Cycle Rate per Minute

 
Take as many readings as necessary.  The 

Average and Fastest 

 rates can be displayed by pressing “F”. 

 
 

OPERATING THE SPEED TIMER 
 
MEMORY RECALL DIRECTION 

 
Select between ascending “UP” or descending “DN” memory recall direction by pressing “D” while the 
Speed Timer is in the reset position. 
 
The recall direction cannot be selected while the Speed Timer is running or not in the reset position. 
 
(1)

 

For Single Lap Events:   Press “A” to start.  “RUN” indicator appears.  Press “A” again to stop the 
timer. “STOP” indicator appears.  The speed will appear in the right side of the upper row of the 
display and the time will appear in the lower row of the display. 

 

Press “B” to reset to all zeros. 

 
(2)

 

For Multiple Lap Events:   Press “A to start, “RUN” indicator appears.  Press “B” to take Lap readings.  
Lap Time will appear in the lower row of the display, Lap Speed in the upper row and Lap Number in 
the Lap Counter.  Continue to press “B” to take as many lap readings as necessary.  The SC-554 will 
record up to 999 laps. 

 

 

Memory Recall in ascending 
order 

Lap Speed for lap 47 is 
150.369 mph

Lap Counter:  
Previous Lap is #47 

Time is running 

Lap Time for lap 47 is 39.91 
seconds 

 
 
 
The Lap Counter will increase by one (1), each time a Lap reading is taken. 
 
The previous Lap Time will remain frozen in the lower row for 15 seconds, at which time it will 
automatically release to the current running lap time.  Or, you can manually release the time by pressing 
“C”. 
 

Summary of Contents for SC-554

Page 1: ...s activated by pressing a pushbutton Once you are familiar with the SC 554 s operation you will be ready to enjoy its many functions The starting point for any operation is the NORMAL TIME mode You ma...

Page 2: ...up to Previous 30 Laps in Ascending up or Descending down Order Automatic Lap Counter up to 999 Laps Enter Distance Precise to 1 1000 Mile or Kilometer 1 100 Second Resolution up to 24 Hours Automatic...

Page 3: ...s C to arm or disarm your alarm and chime The sequence is 1 Alarm ON Chime OFF 2 Chime ON Alarm OFF 3 Alarm ON Chime ON 4 Alarm OFF Chime OFF When armed the alarm will sound when the Alarm Time coinci...

Page 4: ...le using the memory You may also return to the last previous reading at any time by pressing C AVERAGE LAP TIME MAXIMUM FASTEST LAP TIME The Average and Fastest Lap Times can be displayed at any time...

Page 5: ...frozen in the upper and lower rows of the display You may press E to release the frozen display to the current running LAP and SPLIT times or the SC 554 will automatically do so after 15 seconds Upon...

Page 6: ...t are Water Ski Slalom Course 850 feet 0 161 mile Pitcher s Mound Baseball 60 5 feet 0 011 mile Pitcher s Mound Youth 47 feet 0 009 mile Pitcher s Mound Softball 45 47 feet 009 mile Convert meters to...

Page 7: ...r is in the reset position The recall direction cannot be selected while the Speed Timer is running or not in the reset position 1 For Single Lap Events Press A to start RUN indicator appears Press A...

Page 8: ...perate unless a distance has been entered 2 The SC 554 will measure up to 24 hours or 999 laps LIMITED WARRANTY OUR BASIC POLICY Marshall Browning International Corporation MBI Corp warrants to the or...

Page 9: ...er resistant avoid immersing or exposing it to water steam or other forms of moisture WHEN YOU REQUIRE SERVICE If your timepiece ever requires factory servicing you can send it directly to MBI Corp 11...

Reviews: