2
Application
The Robertshaw RS6000C family of thermostats is designed to control
gas, electric, oil, heat pump, and millivolt heating and electric cooling
systems. The RS6220C is a two stage thermostat and the RS6320C
can support three stages of heating and two stages of cooling in heat
pump applications.
The RS6000C thermostats can have a schedule programmed for
each day.
IMPORTANTSAFETYINFORMATION
WARNING:
• Always turn off power at main fuse or circuit breaker panel before
installing, removing, cleaning, or servicing thermostat.
• Read all the information in this manual before installing
this thermostat.
• This is a 24V AC low-voltage thermostat. Do not install on voltages
higher than 30V AC.
• All wiring must conform to local and national building and electrical
codes and ordinances.
• Do not short (jumper) across terminals on the gas valve or at the
system control to test installation. This will damage the thermostat
and void the warranty.
• Do not connect ground to any terminal in this unit.
• This thermostat is configured with automatic compressor protection
to prevent damage because of short cycling or extended power
outages. Short cycle protection provides a delay between heating
and cooling cycles on heat pumps.
Detailed mounting and wiring instructions are explained in the
Installation Manual.
Refer to the Pop-Up Wizard section in the installation manual for a
complete list of factory defaults and contractor settings.
ProvidingPowertotheThermostat
For wiring diagrams refer to the Installation Manual.
The thermostats will operate using 24V AC or two AA batteries. When
the two AA batteries are installed the thermostat will continue to run if
the 24V AC fails.
Summary of Contents for RS6000