EN
EN - 14 -
6 Troubleshooting
SYMPTOMS
POSSIBLE REASONS
SOLUTIONS
Light does not switch on
No lamp installed
Put a lamp
The lamp is installed but
defective
Control / replace the lamp
The lamp compartment is not
properly tightened
Tighten the two knobs to activate the
microswitch contactors
Defective micro-switches
Change the micro-switch(es)
Electrical connection
Check the connections
Faulty power supply
Replace the power supply
The beam is not uniform
The lamp is not aligned
Replace the lamp
Peak/Flat adjustment
Turn the knob to reach the expected
adjustment
Non compatible lamp
See the list of compatible lamps (page EN-6)
5 Service
5.1 Preventive maintenance
5.1.1 Frequency
General maintenance should be performed at least once a year or more frequently if the
equipment is operated in adverse conditions (smoke, heat, humidity, touring, etc.).
5.1.2 General visual check
• No trace of heat.
• No loose contacts.
• No missing parts.
• Tighten mechanical assemblies (screws, bolts and nuts, ground connections, etc.).
5.2 Analysis
If there is still a problem after the troubleshooting procedures (see part 6.),
contact RJ distributor with the following information:
• Model, version and serial number of the product.
• Description of the problem.
5.3 Exploded view / Spare parts list
⇒
Available on
www.robertjuliat.com
⇒
Or on request through our Service departement
Summary of Contents for Tibo-505
Page 10: ...EN Step 1 3 3 Accessories 3 3 1 Front filter holder 3 3 2 Barndoors Step 2 EN 8...
Page 14: ...EN EN 12 4 5 Peak and Flat adjustment 4 5 1 Range 4 5 2 Control Function Peak Flat...
Page 25: ...FR FR 8 3 3 Accessoires Etape 1 Etape 2 3 3 1 Porte filtre 3 3 2 Coupe flux...
Page 29: ...FR FR 12 4 5 R glage Peak Flat 4 5 1 Etendue 4 5 2 Contr le Function Peak Flat...