Power
input
Connector: Neutrik® powerCON TRUE1 TOP Max. 16A.
Power input: 100 => 240V 50/60Hz.
Must be connected directly to AC power.
Do not connect to dimmer power
Power consumption:
@ 230V 50Hz = 0.7A/130W
@ 120V 60Hz = 1.15A/135W
@ 100V 60Hz = 1.40A/135W
2
Power
output
Connector: Neutrik
®
powerCON TRUE1 TOP Max. 8A.
Daisy chain – Maximum quantity of unit on the same
power line:
22 units @ 230V/16A
12 unit @ 120V/15A
10 unit @ 100V/15A
3
Data Out
Connector: XLR 5-pin
4
Data In
Connector: XLR 5-pin / Protocol: USITT DMX 512-A RDM
5
Ethernet
Connector: RJ45 / Protocol Art-Net, sACN + web interface
EN - 3 -
3 Functions
Description
1. Identification plates
2. Data connector (IN and OUT)
3. Power connector (IN and OUT)
4. RJ45 network connector
5. Handle
6. Safety cable attachment point
7. Hanging yoke
8. Tilt index
9. Tilt locking handle
10. Shutters
11. Shutter locking system
12. Lens tube rotation locking button
13. Lens tube access
14. Zoom adjustment
15. Front slot for accessories and gel frame holder
16. Front slot locking system
17. Focus adjustment
18. Gobo holder
19. Iris
1
3
2
4
12
6
5
11
8
18
19
7
17
10
15
13
14
16
9
4
Electrical / Data connections