EN
0%
100%
EN - 11 -
4 Operations
4.1 Light intensity
4.1.1 Range
4.1.3
Parameters
4.1.3.1 Dimming resolution - DMX only
T
Set through RDM protocol, web interface or local control (option)
4.1.3.2 Dimming curve
T
Set through RDM protocol, web interface or local control (option)
Resolution
DMX mode
8 bits – 255 steps
1 - 3
16 bits – 65 535 steps
2 - 4
Remotely with DMX512-A /
Art-Net / sACN protocols.
DMX512-A
4.1.2
Control
or
Web
interface
RDM
compatible
device
RDM
T
Set through RDM protocol or
web interface
Locally, when equipped with
this option
HTP mode (Highest Takes Precedence):
Light output is the highest value of DMX512 command or local control
Focus mode: when standby screen displayed,
Push Exit for 3 secs
→
Light output = 100% for 1 minute
2x times Exit
→
Light output = 0%