EN
EN -19-
5.3
RDM remote control
5.3.1 Protocol:
ANSI E1.20 – 2010 / ANSI E1.37 - 1
For more information about RDM protocol: http://www.rdmprotocol.org/
5.3.2 Functions:
PID
Description
Commentary
ID
UID
Description
get
set
Ox0002
DiscoveryMute
Ox0003
DiscoveryUnmute
Ox0050
(Get) SupportedParameters
X
Ox0060
(Get) DeviceInfo
X
Ox0070
(Get) ProductDetailIDList
X
Ox0080
(Get) DeviceModelDescription
X
Ox0081
(Get) ManufacturerLabel
X
Ox0082
(Get/Set) DeviceLabel
X
X
Ox0090
(Get/Set) FactoryDefaults
X
X
Ox00C0
(Get) SoftwareVersionLabel
X
Ox00E0
(Get/Set) DMX512Personality
X
Ox00E1
(Get) DMX512PersonalityDescription
X
Ox00F0
(Get/Set) DMX512StartingAddress
X
X
Ox0120
(Get) SlotInfo
X
Ox0121
(Get) SlotDescription
X
Ox0200
(Get) SensorDefinition
X
Ox0201
(Get) SensorValue
X
Ox0343
(Get/Set) Curve
E1.37-1
X
X
Ox0344
(Get) CurveDescription
E1.37-1
X
Ox0345
(Get/Set) OutputResponseTime
E1.37-1
X
X
Ox0346
(Get) OutputResponseTimeDescription
E1.37-1
X
Ox0400
(Get) DeviceHours
X
Ox0401
(Get) LampHours
X
Ox0500
(Get/Set) Display Invert
X
X
Ox0501
(Get/Set) Display Level
X
X
Ox0601
(Get/Set) Tilt Invert
X
X
Ox0641
(Get/Set) LockState
E1.37-1
X
X
Ox0642
(Get) LockStateDescription
E1.37-1
X
Ox1000
(Get/set) IdentifyDevice
X
X