E N
- 23 -
5.1.5
Optics
The cleaning of optical parts (lenses) shall be carried out with solutions containing alcohol.
5.2
Analysis
If there is still a problem after the troubleshooting procedures (see section 6), contact RJ distributor
with the following information:
•
Model, version and serial number of the product.
•
Software version (available in menu
Fixture Status
&
Version
)
•
Description of the problem.
5.3
LED reaction according to LED temperature
5.4
Thermal protection
In case of thermal protection start :
•
Remove the LED compartment (See
5.1.4 Dismantling the LED compartment).
•
Control possible overheating indications.
•
Reassemble the LED compartment.
•
Reset the thermal protection by pressing the button.
5.5
Adjusting the maximum light output level
The maximum intensity level of the LED source can be adjusted in the
Fixture Setup
!
Maximum
menu in order to have a consistent fixture fleet. The dimming level is then recalculated depending on
the limitation.
5.6
Exploded view / Spare parts list
*
Available on
www.robertjuliat.com
LED temperature
Fan
5°C
&
65°C
Fan rotation at minimum level
65°C
&
75°C
Fan rotation increases progressively
75°C
&
90°C
Fan at maximum speed
LED intensity dims to zero output (overheating protection)
DMX and system LED feedback (7) is red and temperature is available
in
Fixture Status
menu