1.  Unpack the cabinet. Check the box thoroughly 

  for all hardware and loose parts as follows:

  A. Cabinet 

  B. Hardware Bag 

  C. Shelving 

 

  D. “Z’ Bracket 

  E. Swing Out Magnifying Mirror  

    (or mail in card for SOMM)

2.  Remove the doors from the cabinet and store the  

  doors in the cabinet box. Be sure edges of the doors  

  are protected. Removing the doors allow for easy and 

  fast installation of the cabinet system.

3.  A square and plumb installation insures proper door 

  operation. A square and level are necessary for  

  proper installation.

4.  Improper installation voids the warranty. Installed  

  cabinets cannot be returned.

5.  If you experience any problems with your cabinet, 

  contact your dealer or Robern directly. 

 

Robern• 701 N. Wilson Ave • Bristol, PA 19007

 

Limited Warranty One Year Term on page 8

1.  MP Cabinet

 

Refer to model number designations below 

 

to determine if cabinet was ordered.

2.  Glass Shelves

 

–   4 Shelves are provided 

 

 

with each cabinet 

 

–   3 Shelves are provided 

 

 

with each “E” option cabinet 

3. “Z” Mounting Brackets

 

–  Bracket used for surface  

 

 

 

 

mounted cabinets.

4. Hardware Bag • Contains the Following

 

A.  12 Clear Snap-In Shelf Clips

 

B.  46 Shelf Hole Plugs

 

C.  6 SMS/WOOD Screws #10 X 2”

 

D.  5 SMS/Wood Screws #10 X 3”

 

E.  8 Connector Block Screws #10 X 1/2”

 

F.  2 MP65 Connector Blocks

 

G.  15 Black Screw Head Caps

 

H.   3 Top Mount “Z’ Clip

 

I.  6 Plastic Anchors

Part List – MP Cabinet

MODEL NUMBER DESIGNATIONS

Product  

Type 

Mirror   Mirror 

Hand 

 Options 

 

 

Shape  Edge 

CABINETS  4”D    6”D   8”D

MP16   

(D4)  D6  D8 

A • Arch 

B • Bevel 

N •  L or R Hand 

E •  Electric

MP20 

(D4)  D6  D8 

F • Flat 

P • Plain 

L •  Left Hand 

MP24 

(D4)  D6  D8 

 

 

R •  Right Hand 

LIGHTS

MP-L1.5 or MP-L3.5

SIDEKIT 

 

 

 

 

 

 

MPSK40 

 

 

 

 

B • Bevel 

 

 

 

 

 

 

P • Plain 

 

 

 

 

 

 

 

 

PLEASE NOTE: The MP-L3.5 light fixture requires special consideration concerning overall 

dimensions and brackets. Refer to instructions supplied with the fixture.

 See note below for MP-L3.5

D8 - 8” Deep
D6 - 6” Deep
D8SR - 8” Semi Rec 4”
D6SR - 6” Semi Rec 4”

A • Arch

F • Flat

Cabfax #0476

Summary of Contents for SS476 MP

Page 1: ...t Refer to model number designations below to determine if cabinet was ordered 2 Glass Shelves 4 Shelves are provided with each cabinet 3 Shelves are provided with each E option cabinet 3 Z Mounting Brackets Bracket used for surface mounted cabinets 4 Hardware Bag Contains the Following A 12 Clear Snap In Shelf Clips B 46 Shelf Hole Plugs C 6 SMS WOOD Screws 10 X 2 D 5 SMS Wood Screws 10 X 3 E 8 C...

Page 2: ...TOTAL WIDTH OVERALL XXXXXXXX 52 3 4 XXXXXXXX ROUGH OPENING XXXXXXXX 3 4 XXXXXXXX TOTAL ROUGH OPENING XXXXXXXX 52 XXXXXXXX TOTAL HEIGHT OVERALL FLAT TOP XXXXXXXX 39 3 8 ARCH XXXXXXXX 43 3 8 TOTAL HEIGHT R O ALL SHAPES XXXXXXXX 38 5 8 MP L1 5 MP16D4FBN MP20D4ABRE MP16D4FBN MP L1 5 Single units Multiple Units 1 Each cabinet light and side kit contains special connectors to allow all combinations of c...

Page 3: ...K SCREWS AND CAP USE ONLY FOR RECESSED CABINETS USE 10 PAN HEAD S MS WOOD SCREW 2 OR 3 AND CAP MOUNTING BAR FOR SURFACE MOUNT 6 1 2 CENTERLINE OF ELECTRICAL CONNECTION FOR MP CABINET CENTERLINE OF ELECTRICAL CONNECTION FOR MP LIGHT MP LIGHT MP CABINET OPTIONAL ELECTRIC OUTLET SHELF E OPTION MOUNT UNMOUNT HINGE HERE DOOR HINGE MP CABINET TOP Z CLIP FOR SURFACE MOUNT 3 PER CABINET USE ONLY FOR RECES...

Page 4: ...he circuit Includes two convenient outlets plus a 75 watt door heater The door included with this option is equipped with a disconnect cord The door swings left or right MP lights Use a 120 VAC 15 amp circuit up to 4 lights per circuit The MP 1 5 light fixtures use either a 150 watt tubular incandescent bulb MPIL1 5 sold under the trade names Philinea by Philips and Linestra by Osram or 25 watt T ...

Page 5: ...other a remote The master contains the transformer 7 Fasten fixture at the MP65L connector between the cabinets or MP60 connector at the ends of the cabinet 4 Recessed Cabinet and Light Installation see page 6 for surface inst 16 16 2 MP1640FBN CABINETS 1 MP2040ABRE CABINET 1 MP L1 5 LIGHT KIT 2 PER KIT 36 8 36 3 4 26 26 847 20 A 110VAC CABINET CIRCUIT GFI BREAKER REQUIRED 15 A 110VAC LIGHT CIRCUI...

Page 6: ...ontinued on page 7 LOCATE BRACKET TO CLEAR SINK FAUCETS BY AT LEAST ONE INCH MOUNTING BRACKET 10 X 2 SMS WOOD SCREW 1 X 3 FURRING STRIP BEHIND WALLBOARD OR TILE LOCATED AT CENTER OF BOTTOM EDGE OF CABINET Fig L Recessed Cabinet and Light Installation Continued 8 Install doors following the instructions supplied with the hinge and shown in Figure E on page 3 9 Adjust doors so that there is a gap of...

Page 7: ...stall sequence as shown in figure M 6 The MTSK30 side kit is used to finish the sides of the surface mount installation 6a Attach keyhole bracket to cross bracket using 10 x 1 2 screws Be sure that the keyhole is up as shown on page 8 6b Attach l bracket to cabinet side using 10 X 1 2 screws into cross bracket 6c Attach light fixture 6d Screw two 10 x 1 2 screws into each bracket on SK mirror Leav...

Page 8: ... a damp cloth to clean Mirrors are damaged by the use of ammonia or vinegar based cleaning agents Use rubbing alcohol for stubborn marks B Use no abrasive cleansers on any part of the cabinet Limited Warranty One Year Term ROBERN warrants to the original purchaser that it will at its election repair replace or make appropriate adjustment to products made by this company shown to have significant d...