Robe Stage Faze 1500AT User Manual Download Page 8

8

9

2) Press the Enter button once to switch to the HDCS Menu. The red Timer/Profile-LED will be lit.
3) Adjust settings 1 to 7 according to the chart  below, using the Up/Down buttons and pressing the Mode button to switch between 
the settings.
These settings are stored in non-volatile memory. You don‘t have to run the Profile or press the Enter button in order to „save“ the 
settings. All settings can be changed as described at any time.
4) To start the Profile with the adjusted values, press the Mode button  until „run“ appears on the display (Fig. 8), then press the Enter 
button.
The Timer/Profile-LED flashes, indicating that the Profile is running. The green Active-LED lights as soon as the adjusted Pause (Pre-
-Runtime) has passed and level A has started. 

5) To leave the HDCS menu or quit the Profile, first press the Mode button until „ESC“ appears on the display (Fig. 9). Then press the 
Enter button once to return to the main menu.

6.7 Operating the internal Timer

Fig.10: Adjusting the Pause (Wait-time) 

 

 

Fig.11: Adjusting the faze time

Fig.12:Adjusting the fan 

 

 

 

 

Fig.13:Adjusting the pump 

 

 

 

 

Fig. 14: Quit the Timer-Mode

 

 

With the internal timer, the Faze time and wait time can be adjusted in minutes (0.1 - 99), the pump and fan output can be adjusted in per cent (0 
- 99).
To start the Timer-Mode, press and hold the Mode button  for more than 2 seconds. The red Timer/Profile-LED ] will blink as soon as the machine has 
switched to the Timer-Mode. As long as the timer is in operation, the red Timer/Profile-LED blinks.
The adjusting of the output, Faze time or wait time is the same as in the Standard-Menu. This means you have to press the Mode button repeatedly 
until you reach the required function.
With the Up/Down buttons you can adjust the required functions, then press the Enter button to start the timer. Please note that P and F control Pump 
and Fan, whereas P. and F. control Pause time and Faze (Fog) time (Figs. 10 - 13).
The timer cycle starts with the time shown on the display when you press the Enter button (i. e. P.xx = Starts with wait time, F.xx = Starts with Faze 
time). The timer cycle will not start if you press the Enter button while the pump or fan output setting is shown on the display.
You can switch back to the Standard-Menu by pressing the Mode button for more than 2 seconds or by pressing the Mode button repeatedly until 
„ESC“ shows on the display and then press the Enter button once.

Summary of Contents for Stage Faze 1500AT

Page 1: ...Version 1 1 ...

Page 2: ...e device 4 5 Fluid 5 5 1 General notes 5 5 2 Filling the fluid tank 5 6 Operatting the StageFaze 1500 AT 5 6 1 Selecting a location 5 6 2 Putting into operation 6 6 2 Switching the StageFaze 1500 AT off 6 7 Cleaning care and maintenance 9 8 Troubleshooting 9 9 Specifications 9 StageFaze 1500 AT ...

Page 3: ...hine output area is very hot Avoid coming within 60 cm of the output nozzle during operation Keep a minimum distance of 60 cm to all flammable combustible objects and objects sensitive to heat Locate the Faze machine in a well ventilated area Never cover the unit s vents Never aim the output nozzle at open flames If the supply cord is damaged it must be replaced by manufacturer or its service agen...

Page 4: ...s no evident damage caused by transportation In the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your ROBE distributor for assistance 4 Description of the device Front view Rear view 1 Nozzle 8 Tilt lock 2 Control panel 9 Power cord 3 Handle 10 Powe switch 4 Fluid tank 11 Fuse holder 5 Fluid tube 12 DMX IN OUT 3 pin XLR 6 F...

Page 5: ...re between 10 C and 40 C and the relative humidity below 80 This model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket it is important that the fog does not shoot directly at any one s face Overhead installation 1 Bolt the clamp C to the omega holder D 2 Fix the omega holder on th...

Page 6: ... cooled down This will ensure that no fluid remains in the vaporizer to come out as droplets when the device is switched on next time 6 3 Control Choices Fig 1 Adjusting the pump output Fig 2 Adjusting the fan output Fig 3 Adjusting the DMX start address Fig 4 Changing to the Profile Mode Fig 5 Switching the device Off You may control the StageFaze 1500 AT externally through the 3 pin or 5 pin XLR...

Page 7: ... 1 99 by pressing the Up or Down button 3 Press the Mode button again until an F and two figures appear on the display see Fig 2 4 With the Up or Down button the fan data can now be adjusted 5 Press the Enter button once to start the machine The green Active LED will be lit 6 6 Faze Density Control System HDCS Fig 6 Adjusting the Pause Pre Runtime Fig 7 Adjusting the pump Fig 8 Start the profile F...

Page 8: ...it the Timer Mode With the internal timer the Faze time and wait time can be adjusted in minutes 0 1 99 the pump and fan output can be adjusted in per cent 0 99 To start the Timer Mode press and hold the Mode button for more than 2 seconds The red Timer Profile LED will blink as soon as the machine has switched to the Timer Mode As long as the timer is in operation the red Timer Profile LED blinks...

Page 9: ...s properly connected with the brass coupling Check whether the fluid filter in the tank is clogged Check whether the fluid tube is twisted or defective Trouble The yellow LED at the machine does not light up only when running via DMX Cause Connection from the machine to the desk is faulty Check whether the plug is plugged in correctly Check whether the cable is defective Check whether the DMX star...

Reviews: