![Robe Stage Faze 1500AT User Manual Download Page 7](http://html.mh-extra.com/html/robe/stage-faze-1500at/stage-faze-1500at_user-manual_1468985007.webp)
6
7
6.4 Operating via DMX 512
Connecting the StageFaze 1500 AT to a DMX desk, use the 3XLR sockets [12], at the rear side of the fixture. As soon as the machine receives a
correct DMX signal, the yellow DMX LED will be lit.
Please note: The StageFaze 1500 AT uses two channels on your DMX desk! First Channel = Pump, second Channel =Fan
Adjusting the DMX start address
1) Press the Mode-button [14] at the control panel until three figures appear on the LED-display [17] (see Fig. 3).
2) Adjust the required start address by pressing the Up- or Down-button [15].
3) Save the start address by pressing the Enter-button [16] once. The start address will now also be saved when you disconnect the machine from
the mains supply.
Adjusting the pump and fan output
If you run the machine via a DMX desk you can adjust the pump and the fan directly from the desk from 1 to 99%.
The adjusted channel controls the pump, the following one controls the fan.
6.5 Stand alone
The StageFaze 1500 AT
can be used in the Stand alone mode. In this mode all data for the pump and the fan must be adjusted directly at the ma-
chine.
Adjusting the pump and fan output
1
) Press the Mode-button at the control panel until a P and two figures appear on the LED-display (see Fig. 1).
2) Adjust the desired data (1 - 99%) by pressing the Up- or Down-button .
3) Press the Mode-button again until an F and two figures appear on the display (see Fig. 2).
4) With the Up- or Down-button the fan data can now be adjusted.
5) Press the Enter-button once to start the machine. The green Active-LED will be lit.
6.6 Faze-Density Control System(HDCS)
Fig. 6: Adjusting the Pause (Pre-Runtime)
Fig. 7: Adjusting the pump
Fig. 8: Start the profile
Fig. 9: Quit the profile
With the HDCS, an individual profile for a show can be programmed. Two Levels (Level A and B) with different pump and fan values and different
run-times can be programmed (Level A = settings 2, 3, 4 / Level B = settings 5, 6, 7). Also a pre-runtime can be programmed in (setting 1) which tells
the machine when it should start to run.
For example: The machine shall start to run after 30 Minutes (setting 1). Then the stage should be filled with Faze within 10 Minutes. Therefore a high
pump and fan output should be adjusted and a time of 10 Minutes (setting 2, 3, 4).
After 10 Minutes high output, pump and fan shall go down automatically to a lower step and fill the stage with Faze for another hour (setting 5, 6, 7).
See diagram on page
8
also.
The following Profile settings can be adjusted:
1. Pause (Pre-Runtime) 0 - 99 min
2. Pump (Level A) 1 - 99 %
3. Fan (Level A) 1 - 99 %
4. Run-Time (Level A) 0 - 99 min
5. Pump (Level B) 1 - 99 %
6. Fan (Level B) 1 - 99 %
7. Run-Time (Level B) 0 - 99 min
Using the profile
1) Press the Mode button repeatedly until „Pro“ appears on the display (seeFig. 4).
Summary of Contents for Stage Faze 1500AT
Page 1: ...Version 1 1 ...