![Robe Robin DLX SPOT User Manual Download Page 7](http://html.mh-extra.com/html/robe/robin-dlx-spot/robin-dlx-spot_user-manual_1468975007.webp)
7
4.2 Replacing gobos
DANGER!
Install the gobos with the device switched off only.
Unplug from mains before!
Static gobos
1. Disconnect the fixture from mains and allow it to cool.
2. Remove the top plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Gently skew the gobo module to release it from the hole in the static gobo wheel and pull it up.
4. Insert the new gobo module spring holder under the distance stop and push the gobo module into hole in
the static gobo wheel
.
5. Replace the top cover before applying power.
Rotating gobos
1. Disconnect the fixture from mains and allow it to cool.
2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Gently pull up the gobo holder from the rotation gobo wheel
.
4. Remove the spring gobo-lock with an appropriate tool (e.g. small-bladed screwdriver) and remove it.
Do not touch the surface of the pattern of the glass gobo.
5. Remove the original gobo and insert the new one (glazy side towards the light source). Insert the spring-
gobo lock to secure it in the gobo holder.
6. Insert the gobo holder back under the distance slots into rotating gobo wheel
.
5. Replace the bottom cover before applying power.