![Robe Robin DLX SPOT User Manual Download Page 29](http://html.mh-extra.com/html/robe/robin-dlx-spot/robin-dlx-spot_user-manual_1468975029.webp)
9
Temper.Sensor Error
The message informs you that the communication betwen the head temperature sensor and the main proces
-
sor failed.
Tilt Error 1
(Tilt Error 2)
This message will appear after the reset of the fixture if the head´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head is not
located in the default position after the reset.
Pan Error 1
(Pan Error 2)
This message will appear after the reset of the fixture if the yoke´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The yoke is not
located in the default position after the reset of the fixture.
Prism Error 1 (Prism Error 2 )
The messages will appear after the reset of the prism wheel if this wheel is not located in the default position.
Zoom Error 1 (Zoom Error 2 )
The messages will appear after the reset of the zoom module if the zoom lens is not located in the default
position.
Focus Error 1 (Focus Error 2 )
The messages will appear after the reset of the focus module if the focus lens is not located in the default.
Gobo Carousel Error 1 (Gobo Carousel Error 2 )
The messages will appear after the reset of the rotating gobo wheel if this wheel is not located in the default
position.
Gobo rotation Error 1 (Gobo Rotation Error 2 )
The messages will appear after the reset of the rotating gobo wheel if the rotating gobos are not located in the
default positions.
Static Gobo Error 1 (Static Gobo Wheel Error 2 )
The messages will appear after the reset of the static gobo wheel if this wheel is not located in the default
position.
Faulty battery
The battery on the display board is exhausted and should be replaced immediately.
Clean Air Filters
The message informs that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean air
filters and reset this counter.
10. Technical Specifications
Electrical
Power supply:.........................electronic auto-ranging
Input voltage range:............... supply 100-250V, 50-60Hz
Live Fuse:...............................T 8 A
Neutral Fuse:..........................T 8 A
Max. power consumption* (RGBW=full):...............550W at 230V ; power factor= 0.97; I=2.4A
Typical power consumption* if only one colour is on:
Red=full:...............160W at 230V ; power factor= 0.85; I=0.8A
Green=full:..............210W at 230V ; power factor= 0.9; I=0.98A
Blue=full:..............185W at 230V ; power factor= 0.88 I=0.88A
White=full:..............215W at 230V ; power factor= 0.9; I=1 A
*Allow for a deviation of +/-10%
Optic
Light source: RGBW LED module
RGBW or CMY colour CTC