Robe REDBLINDER 2-48 User Manual Download Page 12

1

Following item are common for all zones:

MACr.

  - a macro selection,value 0-255

Stro.

  - a strobe,value 0-255

dimr.

  - a dimmer,value 0-255

F.tim. 

-  fade time,value 0-255 *

S.tim. 

-  standing time,value 0-255 *

COP.

    - copying the current prog. step to the next prog. step.

Press  [ENTER]-button to confirm adjusted value .

5.Repeat steps 3 and 4 for next  prog.step.If you want to copy current prog. step to the next prog.step, select 

option "COPY."and  confirm it by pressing  [ENTER].

*Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time 

value: 

DMX

Time

[sec.]

DMX

Time

[min.]

DMX

Time

[min.]

DMX

Time

[min.]

DMX

Time

[min.]

1

0.1

50

4.

105

18.4

160

42.7

215

77

2

0.4

55

5

110

0.

165

45.4

220

80.7

5

.5

60

6

115

170

48.2

225

84.4

10

10

65

7

120

4

175

51

230

88.2

15

.5

70

8.2

125

6

180

54

235

92

20

40

75

9.4

130

28.2

185

57

240

96

25

6.5

80

10.7

135

0.4

190

60.

245

100

30

90

85

1

140

32.7

195

6.4

250

104

35

1.5

90

1.5

145

5

200

66.7

255

108

40

160

95

15

150

37.5

205

70

45

0.5

100

16.7

155

40

210

73.5

Exact expression of the time value follows the formula: time[sec.]=(DMX value)

/10.

If Item "

AUto

" is on,the fixture in DMX mode  remembers last running program and this program will run after 

switching on the fixture.

7.3 Manual mode

 

This menu gives access to the control of the fixture channels by means of the control buttons.

Use [UP] and [DOWN] buttons until the display shows "

MAn.C.

" menu.Press [ENTER] button and by using [UP] 

and [DOWN] buttons select desired effect,press [ENTER] and and by using [UP] and [DOWN] buttons adjust 

desired DMX value for selected effect.Confirm by [ENTER].

rEd

 

- all red LEDs  saturation,value 0-255   

rEd.1

  - a red LEDs 1 saturation,value 0-255

GrEE.

  - all green LEDs  saturation,value 0-255  

GrE.1

  - a green LEDs 1 saturation,value 0-255

bLuE

  - all blue LEDs  saturation,value 0-255   

bLu.1

  - a blue LEDs 1 saturation,value 0-255

rEd.2

  - a red LEDs 2 saturation,value 0-255   

MACr.

  - a macro selection,value 0-255

GrE.2

  - a green LEDs 2 saturation,value 0-255 

Stro.

  - a strobe,value 0-255

bLu.2

  - a blue LEDs 2 saturation,value 0-255   

dimr.

  - a dimmer,value 0-255

7.4 Test sequences

Use the item to run a special demo-test sequences without an external controller,which will show you some 

possibilities of using the fixture.

Summary of Contents for REDBLINDER 2-48

Page 1: ...version 1 0 ...

Page 2: ... ...

Page 3: ... between fixtures 6 4 3 Rigging the fixture 6 4 4 Fitting the frost filter 7 5 REDBlinder 2 48 DMX protocol version 1 0 8 6 REDBlinder 2 48 Control menu map 10 7 Control board 11 7 1 Addressing the REDBlinder 2 48 11 7 2 Program running 11 7 3 Manual mode 12 7 4 Test sequences 13 7 5 Stand alone mode 13 7 6 Special functions 13 8 Technical Specifications 15 9 Maintenance 16 REDBlinder 2 48 ...

Page 4: ...ce of AC power that complies with local building and electrical rules AC power has to have both overload and short circuit protection CAUTION Avoid looking directly into the LED light beam at close range 2 Operating determinations This product was designed for indoor use only If the unit has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately Th...

Page 5: ...ur socket outlets do not use an adaptor but remove the plug from the cord and discard Carefully prepare the end of the the supply cord and fit a suitable plug The earth has to be connected Cord plug connections Cable EU Cable US Pin International Brown Black Live L Light blue White Neutral N Yellow Green Green Earth 1 Mounting yoke 2 T bar 3 LED modules 3 1 2 Control board 1 5 pin DMX output 2 3 p...

Page 6: ...has to be terminated with a terminator Solder a 120 Ω resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave Always connect output with the input of the next slave until all slaves are connected up to 9 fixtures Cauti...

Page 7: ...he installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property If the fixture shall be lowered from the ceiling or high joists professional trussing systems have to be used The fixture must never be fixed swinging freely in the room Caution Fixtures may cause severe injuries when crashing down If you have doubts...

Page 8: ...ll green LEDs saturation control 0 100 proportional 3 3 0 255 Blue LEDs All blue LEDs saturation control 0 100 proportional 7 4 0 7 8 15 16 23 24 31 32 39 40 47 48 55 56 63 64 71 72 79 80 87 88 95 96 103 104 111 112 119 120 127 128 135 136 143 144 151 152 159 160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 223 224 231 232 239 240 247 248 255 MACRO SELECTION No function Macro 1 Macro 2 ...

Page 9: ... open Opening pulses in sequences from slow to fast Closing pulses in sequences from fast to slow Shutter open Random strobe effects from slow to fast Shutter open step step proportional step proportional proportional step proportional step 9 6 0 255 DIMMER Dimmer intensity from 0 to 100 proportional Zone positions every zone contains two LED modules ...

Page 10: ...n Edit EPG 1 EPG 2 EPG 3 St 01 St 30 P End rEd 0 255 dimr 0 255 F tim 0 255 S tim 0 255 COPY MAn C rEd 0 255 GrEE 0 255 bLuE 0 255 MACr 0 255 Stro 0 255 dimr 0 255 tESt St AL MASt EPG 1 PrG 6 SLA SPEC VErS tEMP bALA On OFF C bAL rEd b 0 200 255 GrE b 0 255 bLu b 0 215 255 dM Pr Mod 1 Mod 2 Mod 3 Mod 4 i bLi On Off UPd no YES ...

Page 11: ...start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing ENTER After having addressed REDBlinder 2 48 you may now start operating RED Blinder 2 48 via your DMX controller 7 2 Program running By enter to this menu a complete overview of all programs is offered from which the program to be run can be selected by pressing ENTER button Selected progra...

Page 12: ...155 40 210 73 5 Exact expression of the time value follows the formula time sec DMX value 2 10 If Item AUto is on the fixture in DMX mode remembers last running program and this program will run after switching on the fixture 7 3 Manual mode This menu gives access to the control of the fixture channels by means of the control buttons Use UP and DOWN buttons until the display shows MAn C menu Press...

Page 13: ...l C bAL White colour balance Using this menu you can set white balance 1 Browse through the menu by pressing the UP and DOWN buttons until the display shows C bAL menu Press ENTER button and rEd b will appear on the display 2 Press ENTER button again and use UP and DOWN buttons to adjust the new maximum value required for the red channel Confirm your choice by pressing ENTER Use the UP and Down bu...

Page 14: ...ff and on the fixture to leave this option 3 It is recommended that you exit all programs before running the Software Uploader 4 Start the Software Uploader program Select desired COM and then click Connect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update All processors will be updated including processors with th...

Page 15: ...am angle Control and programming Protocol USITT DMX 512 Control options DMX Auto trigger Operation modes Master Slave Stand alone Programs 6 build in programs 3 user editable programs up to 30 steps each Display 4 digit LED White colour balance adjusting Manual control of all DMX channels with LED control panel Temperatures Maximum ambient temperature 40 C Maximum housing temperature 80 C Minimum ...

Page 16: ...lint free cloth Never use alcohol or solvents In order to maintain adequate cooling dust must be cleaned from the air vents Replacing the fuse 1 Before replacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the REDBlinder 2 48 with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the fuse holder 4 Install the new fuse in the fuse holder 5...

Page 17: ...17 ...

Reviews: