![Robe Image Spot 250 AT User Manual Download Page 9](http://html.mh-extra.com/html/robe/image-spot-250-at/image-spot-250-at_user-manual_1468959009.webp)
9
The lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may improve light
performance.
Strike the lamp, cancel all effects, open the shutter and dimmer , focus the light on a flat surface (wall) or use
function "
LAAd
" in the Special functions . As the optimum distance of the lamp from lens was adjusted during the
installing or changing the lamp (by turning the screw "A"), it is necessary to adjust only the second position by
turning the screw "B", in order to center the hot-spot (the brightest part of the beam).
If the hot spot seems to be too bright, you can lower its intensity by moving the lamp closer to the reflector. Do so
by turning the srew "A" until the light is evenly distributed.
If the light on the edge seems to be brighter as in the center, the lamp is too close at the reflector. In this case, you
need to move the lamp away from the reflector until the light is evenly distributed and the beam appears bright
enough.
3.2.Inserting/Exchanging rot. gobos
DANGER!
Install the rotating gobos with the device switched off only.
Unplug from mains before!
Turn off the lamp and allow it to cool for at least 5 minutes.Disconnect the fixture from power.
Open the bottom cover of the moving head by loosening the 3 quarter-turn fasteners on the top cover and follow
the instructions below:
1.Gently bend out the gobo holder to release it from the fixative holes and eject it from the pressing snap.
2.Press the ends of the fixation ring together with an appropriate tool and remove it.
Do not touch the surface of the pattern of the glass gobos as the oils from your hands can damage the
pattern.Always load coating away from the light source.
3.Remove the distance ring and gobo and insert the new gobo with distance ring. Press the ends of the fixation
ring together and insert it in the front of the gobo.
4.Put the gobo holder back under the pressing snap and push it to the 3 fixative notches.
CAUTION!
The gobo holder with the magnet must be placed in the same gobo position
as it was placed before gobo replacement!
CAUTION!
Never unscrew the screws of the rotating gobo
as the ball bearing will otherwise be opened!
gobo-glazy side
towards the lamp
fixation ring
distance ring
gobo holder
pressing snap
magnet