32
-
- Fixture code
The option contains identification code (1-9999) for the fixture, which is used for the master/slave operation.
- Adjusting the default positions of gobo wheels
By this function you can calibrate and adjust the gobo wheels to their standard/right positions. Disconnect the
controller.Use the
[Up]
and
[Down]
buttons to browse through the adjusting menu - the display shows step by
step these messages:
"PAn,FPAn, tilt,Ftilt,SPEd,Func,rGob, Grot, Foc, dimr, FCAL"
by which you can adjust
the fixture to the required/desired position (0-255) before the function calibration. Then when the positioning is
finished use the last
"F.CAL."
function (Fixture calibration).
1. Calibration via the control panel
Press
[Enter]
and the
[Up]
and
[Down]
buttons in order to display the following messages:
"rGob,Grot"
for very
smooth function calibration. Select one item by
[Enter]
and use the
[Up]
and
[Down]
buttons in order to adjust
its right value from 0 to 255. Then press
[Enter]
to confirm or
[Mode]
to cancel and return to the menu. When the
calibration is finished, it is necessary to use the
"A.rES."
function in order to write the calibration values to the
memory (EPROM) and to make a reset in order to check the newly adjusted position of the gobo wheel. When the
reset of the fixture is finished, the display will show the
"F.CAL."
message. Press
[Enter]
to repeat the calibration
or
[Mode]
to return to the
"AdJ."
menu.
2. Calibration via the external controller
Connect the DMX controller, press
[Enter]
and the
[Up]
and
[Down]
buttons in order to display the following
message:
"rGob,Grot"
- calibration parameters. Press
[Enter]
.
Now you can calibrate the rotating gobo wheel by your controller. The DMX calibration protocol is described in the
table mentioned below.
DMX Calibration protocol:
After having calibrated required functions press
[Enter]
to confirm (or
[Mode]
to cancel and return to the menu
without reset by the
"A.rES."
function) and use the
"A.rES."
function in order to write the calibration value to the
memory (EEPROM) and to make a reset in order to check the new adjusted positions of the rot.gobo wheel.