8

9

 6. Presss Enter Key after chosen the voltage

 7. The main screen will appear on the display

8. Maintenance and cleaning

Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and 

the fog machine liquid tank immediately after filling.

After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of 80% 

distilled water and 20% white vinegar through the system to prevent the accumulation of particulate matter in 

the heating element. The recommended cleaning regimen is as follows:

1. Empty all fog liquid from machine. Add cleaning solution to tank. Plug unit in and begin warm up.

2. Run unit in a well-ventilated area until tank is empty.

3. Cleaning is now complete.  Refill with fog liquid.

Note: 

 All fog machines are prone to clogging due to the thick consistency of fog liquid and the high temperature 

at which it vaporizes. However, a properly maintained fog machine should provide years of reliable use.

Clean with a dry cloth only. Store dry.

Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges.

DANGER !

Disconnect from the mains before starting any maintenance work!

More complicated maintenance and service operations are only to be carried out by authorized dealers.

Replacing the fuse

Before replacing the fuse, unplug mains lead. Replace the fuse by a fuse of the same type and rating.

Note:

The warranty does not extend to any parts of the Faze 1000 FT that have been subject to misuse or accident. 

Neither does the warranty cover any Faze 1000 FT that has been opened, modified or repaired other than by 

ROBE or its designated distributor.

The warranty will not apply if procedures described in the Instruction Manual are not followed. It is the user's 

obligation to clean and maintain the Faze 1000 FT according to these instructions, and to follow acceptable 

practices for handling electrical devices with heating elements.