2
Air Filters
--- Regular cleaning of the air filters is very important for the fixture´s life and performance.Bildup of dust,dirt
and fog fluid residues reduces the fixture´s light output and cooling ability.The two items of this menu help you to keep
cleaning peeriod of the air filters.
Set alert period
- Cleaning schedule for the fixture depends on the operating enviroment.
It is therefore imposible to specify accurate cleaning interval.This function allows
you to change the cleaning interval of the air filters.This "alert" value is 50 hours and it
is set as default.Inspect the fixture within its 50 hours of operation to see whether cleaning
is necessary.If clening is required,clean all air filters and change the value in this menu
on acceptable level.Min. level of alert period is 10 hours, max. is 00 hours.
Elapsed Time
- The option allows you to read the time which remains to cleaning air filters.
The time period is set in the menu mentioned above.
Expired time period is signalized by a negative mark at the time value and a warning icon
(triangle) on the display with the following message: "Clean Air Filters"
Clean the filters and reset this menu item (by pressing "Enter" button twice while this menu
is highlighted) to start the new time countdown.
Fixture Temperatures
- Select this submenu to read the temperatures of the fixture:
Current
- Select this function to read the current temperatures of the fixture inside (Board
Temp., Ambient Temp.,Near Lamp Temp.)
Maximum nonresetable
-
The function shows the max.temperatures of the fixture inside (Board Temp., Ambient
Temp., Near Lamp Temp.) since the ColorSpot 2500E AT has been fabricated.
Maximum resetable
-
The function shows the maximum temperatures of the fixture inside (Board Temp., Ambient
Temp., Near Lamp Temp.) since the respective counter was last reset. In order to reset desired counter to
0, press [ENTER] twice.
Measurement points:
Board Temp.
- temperature on the main board in the fixture base.
Ambient Temp.
-
temperature of the air which is sucked to the fixture base. This temperature can be different
from the real ambient temperature due to e.g. suction of the hot air from the fixture head to the base if the fixture
is hanging at the ceiling. Please note that the ambient temperature should not exceed 5°C.
Near Lamp Temp.
- temperature in the lamp chamber.
Fans Speed
- Select this function to read the actual speed of the fans(revolutions per minute):
Fan1
- The fan cools the lamp peak
Fan 3
- The fan on the rear left side of the head
Fan 5
- The left fan at the CMY module
Fan 6
- The right fan at the CMY module
Fan 7
- The Fan iside the head
Fan 9
- The fan on the front right side of the head
Location of the fans:
(Top view)