Eminere Side wireless DMX 

 

Fixture´s Amphenol connectors are dust and water protected according to IP 67 by mating with related Amphenol 

connectors. 

They cannot stay disconnected outdoor. 

 

The output panel connector at last fixture in the Eminere Sides chain has to always be covered with the water-

tight cap  to keep declared IP rating.  

 

  Do not connect (disconnect) Eminere Sides to the Booster box and each other when they are under voltage! 

  

 

Direct visibility between a transmitter and the Eminere Side Wireless DMX must be ensured without 

no obstacles (bildings, trees,....). 

Distance between a DMX transmitter and the Eminere Side Wireless DMX depends on transmission range of used 

DMX transmitter, surrounds etc  (we recommend to test behaviour of DMX transmitter with the Eminere Side 

Wireless DMX before installation). 

 

 

Examples of connection

  

 

 

 

 

 

 

 

 

 

 

The Eminere Side can be only linked to a transmitter by running the link procedure at DMX transmitter . 

The Eminere Side can be unlinked from the transmitter by running the unlink procedure at DMX transmitter or by 

switching off/on the Eminere Side three times while the transmitter is switched off. 

During off/on unlink procedure, the Eminere Side has to be switched on for 5 seconds in steps 1-3: 

Step 1: Eminere Off, Eminere On (5s) 

Step 2: Eminere Off,Eminere On (5s) 

Step 3: Eminere Off, Eminere On (5s) 

Step 4: Eminere Off, Eminere On  

Successful unlink is signalized by flashing LEDs at fourth switching the Eminere Side Off and On. If the LEDs flashing 

will not appear, probably the 5 seconds period has not been kept and you have to repeat the Off/On procedure to 

unlink the fixture from the DMX transmitter .   

 

DMX addressing of connected Emineres Side has to be done manually by means of the Robe Universal Interface 

WTX and the software RDM Manager. 

 

Number of connected Emineres Side in DMX chain also depends on their cable length, power voltage and type of 

Emineres Side. 

 

 

Summary of Contents for ANOLIS Side Eminere 2 Wireles DMX

Page 1: ...Version 1 6 ...

Page 2: ...ons 3 2 Fixture exterior view 4 3 Installation 5 3 1 Mounting the fixture 5 3 2 Connection to mains 5 3 3 The Booster box 8 3 4 The Booster box installation 9 4 Technical specifications 14 5 Cleaning and maintenance 18 5 1 Disposing of the product 18 6 ChangeLog 18 ...

Page 3: ... servicing or installing Make sure the data power cable is not damaged by sharp edges Check the fixture and the power cord from time to time Do not install the unit near an open flame During operation the housing becomes hot Refer servicing to qualified service personnel This fixture falls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protectiv...

Page 4: ...ic field higher than 3V m The installation company should check levels of possible interferences above the tested levels E1 E2 E3 given by this standard e g transmitters in surrounding area before installing the equipment Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B Please consider that...

Page 5: ...re attaching the unit is secure 3 2 Connection to mains The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded The Eminere Side is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 120 277 Volts Wiri...

Page 6: ...de can be only linked to a transmitter by running the link procedure at DMX transmitter The Eminere Side can be unlinked from the transmitter by running the unlink procedure at DMX transmitter or by switching off on the Eminere Side three times while the transmitter is switched off During off on unlink procedure the Eminere Side has to be switched on for 5 seconds in steps 1 3 Step 1 Eminere Off E...

Page 7: ... SIDE 3 wireless DMX Voltage Cable length 120V 190V 230V 277V 10 m 28 32 32 32 20 m 28 32 32 32 30 m 19 32 32 32 50 m 12 29 32 32 70 m 8 21 31 32 100 m 6 15 21 31 EMINERE SIDE 4 wireless DMX Voltage Cable length 120V 190V 230V 277V 10 m 21 32 32 32 20 m 21 32 32 32 30 m 15 32 32 32 50 m 9 22 32 32 70 m 6 16 23 32 100 m 4 11 16 23 Cable length is a total cable length among connected Emineres Side w...

Page 8: ...ide 2 Wireless DMX 32 Voltage Cable length 120V 190V 230V 277V 10 m 20 m 30 m 28 50 m 17 70 m 12 24 31 100 m 9 18 21 31 EMINERE SIDE 3 Wireless DMX Max possible number of Emineres Side 3 Wireless DMX 32 Voltage Cable length 120V 190V 230V 277V 10 m 28 20 m 28 30 m 19 50 m 12 24 29 70 m 8 16 24 21 31 100 m 6 12 18 24 30 15 30 21 31 EMINERE SIDE 4 Wireless DMX Max possible number of Emineres Side 4 ...

Page 9: ... on the Booster box to get access to the terminal block 3 and two mounting holes of diameter of 4 6 mm 4 2 Screw the Booster box on a non flammable flat surface and connect cables The Cable gland M20x1 5 for Power IN 5 is intended for a cable of a diameter of 7 13mm Remove the end cap from the cable gland before passing the cable Power connection L N earth Core EU Braun Blue Green yellow Core US B...

Page 10: ...Eminere Side wireless DMX 10 3 Screw the cover 2 back on the Booster box ...

Page 11: ...r of 14 5 mm for the Anolis cable P N 13053138 or P N 13053139 The seal with inner diameter of 14 5 mm serves for cable of diameter 10 14 5mm The seal with inner diameter of 10 mm serves for cable of diameter 8 10mm Parts of the connector 2 Remove insulation from the cable 5 and from individual wires and fasten three terminals on data wires CE version ...

Page 12: ...sion 3 Put parts of the connector on the cable 5 and connect wires to the connector First connect power wires L N Earth and after that data wires D D 0V Avoid excessive torsion of data wires CE version Male Female US version Male Female ...

Page 13: ... 6 5 Screw the clamp ring 2 to the connector 1 insert the seal 3 to the clamp ring 2 and tighten the sealing nut 4 enough During the steps DO NOT TWIST the cable 5 6 Use the same procedure to assemble the connector on the second end of the cable IMPORTANT Do not bend the cable near to the connector minimum distance for bending is 50mm ...

Page 14: ...trical 9 15 30 50 65 100 Bi symetrical 10 x 30 30 x 10 10 x 60 60 x 10 35 x 70 70 x 35 15 x 90 90 x 15 Wallwasher Wide Wallwasher Projected LED Life 60 000 Hrs L70 25 C77F Protection factor CE IP 67 US Suitable for wet location Impact rating CE IK06 Operating ambient temperature range 20 C 40 C 4 F 104 F Operating temperature 67 C Ambient 40 C 153 F Ambient 104 F Connection Input panel connector A...

Page 15: ...ng system Convection Total heat dissipation Eminere Side 2 130 BTU h calculated Eminere Side 3 177 BTU h calculated Eminere Side 4 228 BTU h calculated Weight Eminere Side 2 4 75 kg 10 47 lbs Eminere Side 3 7 0 kg 15 43 lbs Eminere Side 4 8 92 kg 19 67 lbs Dimensions All dimensions in mm inch Eminere Side 2 ...

Page 16: ...Eminere Side wireless DMX 16 Eminere Side 3 Eminere Side 4 ...

Page 17: ...r Cable FF FM 0 25m P N 13053052 Jumper Cable FF FM 0 5m P N 13053053 Jumper Cable FF FM 1m P N 13053054 Jumper Cable FF FM 2m P N 13053055 Jumper Cable FF FM 3m P N 13053056 Jumper Cable FF FM 5m P N 13053057 Jumper Cable FF FM 10m P N 13053058 Waterproof Cover Cap FM ZAHB 0006 P N 17031173 Field Installable Connector FF P N 13053003 ...

Page 18: ...arts please use ROBE OEM parts 5 1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes 6 ChangeLog This section summarizes changes in the user manual Version of the manual Date of issue Description of changes 1 1 07 09 2021 Option Wireless DMX to wired DMX removed 1 2 05 10 2021 New DMX char...