background image

 Calumma XL  

 

22 

5. Software update 

 

Software update of Calumma module has to be done by means of the software ROBE Uploader running on PC. 

The ROBE Uploader is a software for automatized software update of ROBE fixtures. The ROBE Uploader switches 

Calummas to the update mode automatically.  

Please see https://www.robe.cz/robe-uploader/ for more information. 

 

The software update depends on a method of Calummas connection.  

Note:

 Calumma modules in DALI connection and ON/OFF connection cannot be updated.  

 

DMX or Ethernet connection via E-box 

If the option 

Standard

 is selected from the menu 

E-box mode

, the E-box will be updated including connected  

Calumma modules. You have to use the file EminereEbox.lib  in the ROBE Uploader for this operating mode.  

The Standard mode is usually used in IN/OUT connection (without junction boxes). 

 

If the option 

Pass-Thr

 is selected from the menu 

E-box mode

, the E-box will not be updated, only connected  

Calumma modules. You have to use the file Calumma.lib in the ROBE Uploader for this operating mode. 

The Pass-Through mode is usually used in connection with junction boxes. 

 

Examples: 

 

1. By means of DMX connection and RUNIT. IN/OUT connection. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EminereEbox.lib 

Summary of Contents for Anolis Calumma XL MC

Page 1: ...Version 1 0 QR code for user manual ...

Page 2: ...n 7 3 4 Half top hat installlation 8 4 Control and connection options 9 4 1 DMX or DALI 9 4 2 Wireless DMX 10 4 3 Wireless DMX to wire DMX 11 4 4 Power On Off 11 4 5 DMX or Ethernet via E box 12 4 5 1 Booster box 18 4 5 2 Booster box installation 20 5 Software update 22 6 Technical specifications 25 7 Cleaning and maintenance 31 7 1 Disposing of the product 31 8 ChangeLog 31 ...

Page 3: ...ure the power data cable is not damaged by sharp edges Do not install the unit near an open flame Refer servicing to qualified service personnel This fixture falls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack LED light emission Risk of eye injury Do not look into the b...

Page 4: ...eck levels of possible interferences above the tested levels E1 E2 E3 given by this standard e g transmitters in surrounding area before installing the equipment Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B Please consider that unauthorized modifications on the fixture are forbidden due...

Page 5: ...local electrical and construction codes and regulations This device falls under class one and must be grounded The Calumma is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 120 277 Volts 3 2 1 Junction box installation The junction box box falls under protection class I Therefore every junction box has to be connected to a mains socket outl...

Page 6: ... of it The reducing seal for diameter of cable 4 8mm P N 13051388 is enclosed in the Junction box Remove the end cap from the cable gland before passing the cable We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body Cabl...

Page 7: ... 3 Top hat installlation 1 Unscrew the four flat head screws M3x8 1 from the front of the Calumma and remove the flange 2 2 Place the top hat 3 on the Calumma and screw it by means of the four flat head screws M3x8 1 ...

Page 8: ...lf top hat installlation 1 Unscrew the four flat head screws M3x8 1 from the front of the Calumma and remove the flange 2 2 Place the half top hat 3 on the Calumma and screw it by means of the four flat head screws M3x8 1 ...

Page 9: ... Core Connection Black Live L Red Data Blue Neutral N White Data Yellow Green GND Shielding Data ground 0V Up to 32 Calummas can be connected in DMX chain DALI connection IF the 5 cored cable SJTW 5x 14AWG P N 1305 3336 is used for Calumma connection and connection among junction boxes Core Connection Core Connection Black Live L Red Data White Neutral N Orange Data Yellow Green GND Up to 64 Calum...

Page 10: ...05 1508 is used for Calumma connection Core Connection Core Connection Black Live L Red Data Blue Neutral N White Data Yellow Green GND Shielding Data ground 0V DMX connection US IF the 6 cored cable SJTW 6x 14AWG P N 1305 3480 is used for Calumma connection Core Connection Core Connection Black Live L Red Data White Neutral N Orange Data Yellow Green GND Blue Data ground 0V ...

Page 11: ...unction boxes Core Connection Core Connection Black Live L Red Data Blue Neutral N White Data Yellow Green GND Shielding Data ground 0V Up to 32 Calummas can be connected in DMX chain DMX connection US IF the 6 cored cable SJTW 6x 14AWG P N 1305 3480 is used for Calumma connection and connection among junction boxes Core Connection Core Connection Black Live L Red Data White Neutral N Orange Data ...

Page 12: ...default DMX address 1 changes can be done by the E box menu or by RDM Pass Thr Pass through LED modules are switched to an internal parallel connection DMX addressing of connected LED modules has to be done manually by means of the Robe Universal and the software RDM Manager Example with junction boxes Pass Through mode is intended for this connection Max 32 fixtures can be connected to one LED ou...

Page 13: ...e L Red Data White Neutral N Orange Data Yellow Green GND Blue Data ground 0V Number of connected Calummas to one E box output depends on a cable length power voltage type of Calumma and E box operation mode The tables below state max theoretical number of Calummas connected to the one LED output of the E box The tables apply for the Pass Through mode of E boxes Calumma XL MC Voltage Cable length ...

Page 14: ... 50 m 4 10 15 22 70 m 3 7 11 16 100 m 2 5 8 11 200 m 1 3 4 6 500 m 0 1 2 2 Cable length is a total cable length between power supply e g E box and last connected Calumma Example Total cable length L1 L2 L3 L4 L5 L6 ...

Page 15: ...Calumma XL 15 Example with IN OUT cables Standard mode is intended for this connection Note Combination of Calummas and Emineres is also possible ...

Page 16: ...or at last fixture in the Calumma chain has to always be covered with the water tight cap to keep declared IP rating The Calumma modules with IN OUT cables should be connected to the E box which allows power supply of the Calumma modules and their control Do not connect disconnect Calummas to the E box or Booster box and each other when they are under voltage When you change any setting of the E b...

Page 17: ... 200 m 1 3 4 6 500 m 0 1 2 2 Calumma XL SC Voltage Cable length 120V 190V 230V 277V 10 m 10 16 19 23 20 m 10 16 19 23 30 m 7 16 19 23 50 m 4 10 15 22 70 m 3 7 11 16 100 m 2 5 8 11 200 m 1 3 4 6 500 m 0 1 2 2 Cable length is a total cable length between power supply e g E box and last connected Calumma Example Total cable length L1 L2 L3 Notice for the E box Star The tables above state max total nu...

Page 18: ... 54 57 60 63 66 69 72 8 16 24 32 40 48 56 64 72 80 88 12 24 36 48 56 68 80 92 104 17 34 51 68 85 102 119 100 m 2 4 6 8 10 12 14 16 18 20 6 12 18 24 30 36 8 16 24 32 40 4 8 56 12 24 36 48 56 68 80 200 m 1 2 3 4 5 6 7 8 9 10 11 3 6 9 12 15 18 2 1 24 27 30 33 36 39 42 45 48 51 54 57 60 63 66 6 9 72 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 6 12 18 24 3 0 36 42 500 m 1 2 3 4 5 6 7 8...

Page 19: ... 33 36 39 42 45 48 51 54 57 60 63 66 6 9 72 75 78 81 4 8 12 16 20 24 28 3236 40 44 48 52 56 60 64 68 72 76 80 84 6 12 18 24 3 0 36 500 m 1 2 3 4 5 6 7 8 9 10 11 2 4 6 8 10 12 1 4 16 18 20 2 4 6 8 10 1 2 14 16 18 2 0 Example E box Daisy Power supply 230V Cable length 70m fixture Calumma XL SC The Booster box has to be connected after every 11th Calumma XL SC fixture 11 and fixture 22 from 24 fixtur...

Page 20: ... 3 Connect power cable Remove the end cap from the cable gland before passing the power cable The cable gland M20 x 1 5 5 with a standard seal serves for a cable of diameter of 7 13mm for smaller diameter of cable 4 8mm you have to remove the original seal from the cable gland M20 x 1 5 and use the enclosed reducing seal instead of it The reducing seal for diameter of cable 4 8mm P N 13051388 is e...

Page 21: ...Calumma XL 21 Cable gland M20x1 5 4 Screw the cover 2 back on the Booster box ...

Page 22: ...pdated DMX or Ethernet connection via E box If the option Standard is selected from the menu E box mode the E box will be updated including connected Calumma modules You have to use the file EminereEbox lib in the ROBE Uploader for this operating mode The Standard mode is usually used in IN OUT connection without junction boxes If the option Pass Thr is selected from the menu E box mode the E box ...

Page 23: ...T Connection via junction boxes If you use a connection via junction boxes and you need to update connected E box switch the E box to the Standard mode and use the EminereEbox lib in the ROBE Uploader to update E box After updating the E box switch it back to the Pass Trough mode EminereEbox lib Calumma lib ...

Page 24: ...Calumma XL 24 DMX connection For updating of Calumma modules use the file Calumma lib Calumma lib ...

Page 25: ...x 10 10 x 60 60 x 10 15 x 45 45 x 15 15 x90 90 x15 30 x60 60 x30 30 x90 90 x30 Beam Angle Calumma XL SC Symetrical 10 15 25 30 45 65 100 Bi symetrical 10 x 30 30 x 10 10 x 60 60 x 10 15 x 45 45 x 15 15 x90 90 x15 30 x60 60 x30 30 x90 90 x30 Asymmetrical side Asymmetrical forward Projected Lumen Maintenance L90B10 90 000 hrs Ta 25 C 77 F Compatible drivers E box Daisy 1 Output 1 Main power Input Co...

Page 26: ...C 4 F 104 F Connection CE DMX connection Calumma IN Flamar 3x AWG 16 1 x 2x AWG 24 Standard 1m with bare end P N 1305 1508 Interconnecting cables Flamar 3x AWG 16 1 x 2x AWG 24 P N 1305 1508 Junction box Wireless DMX connection Calumma IN Flamar 3x AWG 16 1 x 2x AWG 24 Standard 1m with bare end P N 1305 1508 Junction box Wireless to DMX connection Calumma IN Flamar 3x AWG 16 1 x 2x AWG 24 Standard...

Page 27: ...N 13053423 Jumper Cable FF FM 1 m P N 13053425 Jumper Cable FF FM 2 m P N 13053427 Jumper Cable FF FM 3 m P N 13053428 Jumper Cable FF FM 5 m P N 13053430 Jumper Cable FF FM 10 m P N 13053424 Connection US Wireless DMX connection Calumma IN SJTW 6x 14AWG standard 1m with bare end P N 1305 3480 Junction box Wireless to DMX connection Calumma IN SJTW 6x 14AWG standard 1m with bare end P N 1305 3480 ...

Page 28: ...Calumma XL 28 Dimensions All dimensions in mm inch ...

Page 29: ...Calumma XL 29 Junction box ...

Page 30: ...Calumma XL 30 Booster box ...

Page 31: ...with low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use ROBE OEM parts 7 1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to ...

Reviews: