background image

3

DIP 10 - if switched to ON=test light (the fixture lights at 3200K) 

DIP 11 - has to be switched to OFF position to receive DMX 512 or DALI

DIP 12 - change from OFF to ON position switches the fixture to the update mode.

DMX control

The DMX start address, is the first channel used to receive instructions from the DMX controller. The address 

may be any channel from 1 to 510. DMX address can be set either by DIP switch or by RDM. DMX address 

set by RDM overwrites address set by DIP switch and vice versa.

DIP 11 has to be set in OFF position. DALI commands have priority to DMX operation.

Example of DMX addresses:

DALI control

Addressing of the fixture is made by means of an external DALI controller. The external DALI controller has to 

send activating command (1=ON) to start control of the fixture (and deactivating command (0=OFF) to stop 

control of the fixture).

DIP 11 has to be set in OFF position. DALI commands have priority to DMX operation.

4.RDM 

This fixture supports RDM operation. RDM (Remote Device Management) is a bi-directional communication 

protocol for use in DMX512 control systems, it is the new open standard for DMX512 device configuration and 

status monitoring.

RDM allows you to set DMX address and readout software version of the fixture.

5

Anti-glare ring 

installation

Insert the anti-glare ring (1) into the fixture until three locks (2) snap into slots (3).

Summary of Contents for Ambiane

Page 1: ...nit Do not use the unit near high humidity or water or expose to rain Do not install the unit near an open flame Do not install the unit in dirty dusty or badly ventilated location Sufficient air accessing to the housing of the unit has to be ensured there must not be any heat or anti noise insulation within a 0 6m x 0 6m area around the unit non IC rated fixture Alvays switch off power suply of t...

Page 2: ...power is enabled If the fixture is supplied via the secondary power the light output of the fixture is a white colour 3200K and its light intensity can be set by a trimmer The fixture can be controlled by one of the following methods DMX 512 DALI The fixture is equipped with two DMX and DALI connection blocks for easy connection to DMX or DALI chain In Out method DMX connection Power connection PC...

Page 3: ...n Example of DMX addresses DALI control Addressing of the fixture is made by means of an external DALI controller The external DALI controller has to send activating command 1 ON to start control of the fixture and deactivating command 0 OFF to stop control of the fixture DIP 11 has to be set in OFF position DALI commands have priority to DMX operation 4 RDM This fixture supports RDM operation RDM...

Page 4: ...expectancy minimum 50 000 hours Operating ambient temp range 20 C 45 C 4F 113F Operating temperature 75 C Ambient 35 C 167 F Ambient 95 F Total heat dissipation 136 BTU h calculated Cooling convection Total heat dissipation 136 BTU h calculated Housing alluminium Weight 1 8 kg Installation method via two spring fasteners Protection factor IP 20 IC rating non IC rated Power DMX DALI connection scre...

Page 5: ...5 10 Dimensions mm inch 5 Version 2 0 June 23 2017 Specifications are subject to change without notice Made in CZECH REPUBLIC by ROBE LIGHTING s r o Palackeho 416 20 CZ 75701 Valasske Mezirici ...

Reviews: