background image

The discharge voltage is fixed, and is detected automatically.
When the discharge process is finished there follows a pause
(mode „P“) lasting three minutes. The charge process then
starts.

If you wish to discharge the battery only, you can interrupt the
cycle at this point by pressing the „DISCHARGE-CHARGE“
button during the discharge process.
You can interrupt the process at any time during the charge
cycle by pressing the „CHARGE“ button. Once the complete
cycle has been completed, mode „F“ appears on the screen,
and you will hear the beeper sound.
During and after the charge process the screen shows the
discharged capacity with the „-“ prefix, and the charged-in
capacity with the „+“ prefix; the two values alternate on the
screen.

The charger now switches to a trickle charge using a current
within the range 50 to 200 mA, depending on the type of bat-
tery connected to it.

Error messages:

If an error occurs, the appropriate error message appears on
the screen and you will hear the beeper sound. After you
eliminate the problem and cancel the message by pressing
any button, the warning signal is switched off, and after about
three seconds the main screen reappears.

Input voltage lower than about 9.5 V

Open circuit during the charge or charge / 
discharge process

Reverse polarity at the charger output

Program started with no battery connected

Operating instructions

POWER PEAK PLUG &CHARGE

Order No.

8379

9

The main screen for mode „C“ now appears.

Once the program is started, the unit carries out a „battery
check“. During the charge process the charger checks the
state of the battery without current every minute, and adjusts
the automatic or manual charge current to the optimum level
afterwards.
The current data is displayed on the screen during the
charge cycle and at the end of the cycle.
Pressing the „CHARGE“ button briefly always interrupts the
charge process (mode „R“).

Once the charge process is finished, the beeper sounds and
mode „F“ is displayed. The charger now switches to a trickle
charge using a current within the range 50 to 200 mA,
depending on the type of battery connected to it.

When disconnecting the NC battery always disconnect
the pack from the charge leads first, and only then dis-
connect the charge leads from the charger.

Discharging / charging batteries

Connect the NC battery with correct polarity.
Press the „DISCHARGE“ button briefly to activate the auto-
matic discharge program.
If you wish to set the discharge current manually hold the
DISCHARGE-CHARGE button pressed in continuously; the
current advances in 0.5 A increments. Caution: observe the
current limits stated by the battery manufacturer.
If you are discharging a radio control system battery
check that the cable cross-section and connector do not
place further restrictions on the charge rate.

Release the button once the correct discharge current is
shown on the screen. This activates the program using the
fixed discharge current.

The main screen for mode „D“ now appears.

Once the discharge / charge program has started, you can
set the current for the subsequent charge cycle manually
using the Charge button. If you do not do this, the charge
process will be carried out with the current set automatically.

0:00:10    0.11A

C

9.08V   + 0 mAh

SET DISCHARGE
CURRENT AUTO

SET DISCHARGE
CURRENT 2.5A

0:00:10    0.17A

D

9.00V   - 0 mAh

INPUT BATTERY
LOW VOLTAGE

CHECK THE BATT.
OPEN CIRCUIT

OUTPUT BATTERY
REVERSE POLARITY

NO BATTERY
INSERT BATTERY

(automatic)

(manually)

Summary of Contents for 8379

Page 1: ...Bedienungsanleitung Operating instructions Notice d utilisation POWER PEAK Plug Charge No 8379...

Page 2: ...res 2 x 16 Zeichen LC Display Die Abschaltung des Ladevorganges erfolgt automatisch bei voll geladenem Akku nach dem Delta Peak Verfahren Die Stromversorgung L fter OUTPUT ENTLADEN LADEN DISCHARGE CHA...

Page 3: ...der Betriebsart in H S t u n d e n M M M i n u t e n SS Sekunden A Lade Entladestrom in Ampere S Anzeige der Betriebsart siehe unten V NC Akkuspannung in Volt Z Vorzeichen f r Kapazit tswert Die ein...

Page 4: ...r ft das Ladeger t im Minutenzyklus stromlos den Akkuzustand und stellt danach den optimalen oder manuell eingestellten Ladestrom wieder ein W hrend oder am Ende des Ladezyklusses k nnen die aktuellen...

Page 5: ...dekabel No 8262 F Serien Sender No 8263 Internationale Serie Sicherheitshinweise Bei l ngerem Nichtgebrauch das Ger t von der Stromquelle trennen und eventuell angeschlossenen Akku abnehmen Beim Aufst...

Page 6: ...robbe Modellsport GmbH Co KG Metzloserstr 36 36355 Grebenhain HJJ...

Page 7: ...meters are displayed on a large clearly legible 2 x 16 character LCD screen Power supply Fan OUTPUT ENTLADEN LADEN DISCHARGE CHARGE Button Controls CHARGE button For starting and stopping the charge p...

Page 8: ...rs MM minutes SS seconds A Charge discharge current in Amps S Display of mode of operation V NC battery voltage in Volts Z Capacity prefix The charged in capacity is indi cated by and the dis charged...

Page 9: ...sts the automatic or manual charge current to the optimum level afterwards The current data is displayed on the screen during the charge cycle and at the end of the cycle Pressing the CHARGE button br...

Page 10: ...vary according to the number of cells in the pack Never terminate the charge or discharge cycle by discon necting the battery All error messages remain on the screen for about three sec onds after yo...

Page 11: ...Peak L automatisme de commutation se charge d une com mutation parfaitement efficace Alimentation lectrique Ventilateur OUTPUT Sortie Touche de d charge charge ENTLADEN LADEN DISCHARGE CHARGE l ments...

Page 12: ...heures MM minutes SS secondes A courant de charge d charge en amp res S affichage du mode V tension de l accu Cd Ni en volts Z pr fixe de la valeur capacitive La capacit charg e est rep r e par et la...

Page 13: ...du cycle de charge il est possible de lire les informations en cours sur l cran Lorsque la touche LADEN est bri vement activ e la proc dure de charge est en principe interrompue mode R Lorsque la proc...

Page 14: ...opin es ou la destruction de l accu ou du chargeur Cordons de charge directe recommand r f 8262 metteurs de la s rie F r f 8263 s rie internationale Consignes de s curit Lorsque l appareil n est pas u...

Reviews: