Measuringitems
Condion
Unit
Normal
Limit
Tuning Frequency Range
Low End
MHz
87,5
±0.5
87.5
High End
MHz
108,25
±0.5
108.5
Intermediate Frequency
MHz
10,7
±0.35
10.75
90MHz
dB
22
18
98MHz
dB
22
18
106MHz
dB
22
17
90MHz
dB
26
20
98MHz
dB
26
20
106MHz
dB
26
20
IF Rejection
90MHz
dB
40
35
35
Image Rejection
106MHz
dB
45
30
30
AM Rejection
98MHz
dB
40
30
30
Distortion at Standard Output
98MHz
%
10% THD Output Power, 75 KHz Dev.
98 MHz
mW
280
250
Low Frequency
Hz
100
125
100
High Frequency
Hz
4500
4000
3900
•
6dB Audio Fidelity
•
30dB Quieting S/N Sensitivity
Max Sensitivity
MODULATION :1KHZ 22.5KHz SPEAKER IMPEDANCE: 8 OHM REV:1
CC:
AM/FM RADIO
SUPPLY VOLTAGR: AC230V50HZ STANDARD POWER OUTPUT: 50mw 2OF2
Summary of Contents for CLR-2465
Page 1: ...Service Manual CLR 2465 R CLR 2465 Service Manual CLR 2465 ...
Page 4: ......
Page 5: ......