Roadragon LTS-3YT User Manual Download Page 13

For example

HX,120#,

set the wake up time is 120 minutes.

ZZ,<A>[,T1,T2]#

Track Mode
A: A=1,

Enter track mode

A=0

Exit track mode

T1:

Set upload interval in track mode

Unit

second

value range

5-300 seconds

T2:

Set the continue tracking upload interval

unit: minutes

value range

5-57600 minutes

For example

ZZ,1,10,60#

enter track model

upload interval is 10 seconds, enter sleep mode

after 60 minutes

WAKEUP,T1[,T2[,T3

[,T4]]]#

Set a multiple points upload parameter, maximum 4 points T1…T4, it
is allowed to set 1 clocks or more clocks, maximum supports 4

For example

WAKEUP,0800,1000,1530,1900#

They are all clock points which will wake up at 8:00

10:00

15:30

19:00 and upload terminal parameter info

FALL,A#

A=3 Open

tamper alarm

no track

A=2 Open

tamper alarm

track 15 minutes

every 300 seconds

A=1 Close tamper alarm
A=0 Open

tamper alarm

track 60 minutes

every 60 seconds

Default :A=0

For example; FALL,0# ,Open

tamper alarm

track 60 minutes

every 60 seconds

UTC,TTTT#

Set Time zone Range 780~-720
For example

UTC,480#,Platform positioning time is Beijing time

*11*4#

Check terminal communication status
“Online” represent online
"Offline" represent offline
Link represent connect to the server
Ip, port, apn, terminal id, software version number followed by status

*22*1#

terminal restore to factory

*22*4#

Restart terminal

*77*0 number#

Set center number 1
For example

*77*0123456# center number 1

123456

*77*0#

delete center number 1

*77*2 number#

Set center number 2
For example

*77*2123456# center number 2

123456

*77*2# delete center number 2

VPN,apn,user,pswd#

Set APN, user name

passport

For example

VPN,APNAPDemo.com.attz,internet,internet#

Summary of Contents for LTS-3YT

Page 1: ...LTS 3YT User manual User Manuel LTS 3YT...

Page 2: ...7 Backend Specific Commands 7 4 1 8 Blind zone compensation 7 4 1 9 E Sim 8 4 2 Extention Optional Functions 8 4 2 1 Light Sensor 8 4 2 2 Motion Detect 8 4 2 3 Temperature and humidity detect 8 Chapte...

Page 3: ...LTS 3YT User manual 1 Chapter One Product Photo...

Page 4: ...t different needs of customers 3 Low Voltage The working voltage can be decreased to 10 A during sleep mode to make sure the unit would work longer 4 The device supports 4G 3G 2g networks in most part...

Page 5: ...4G network TDD LTE FDD LTE 3G network WCDMA 2G network GSM GPRS GNSS Support GPS BD Dual mode GPS L1 1575 42MHz C A Code BD B1 1561 098MHz Dimension 205mm 68mm 27mm L W H Weight 200g 5g Waterproof IP6...

Page 6: ...on includes Position status longitude and latitude GSM Signal Strength GPS numbers battery voltage etc the upload interval can be configured the unit is able to work no less than 365 days 4 1 2 AGPS T...

Page 7: ...location data according to the preconfigured interval by customer until a stop tracking command is received 4 1 6 Clock mode The terminal could verify the timely wake up time points maximum 4 points c...

Page 8: ...e terminal to send alarm this function is for detecting the door open alarm purpose 4 2 2 Motion Detect Built in high sensitive low consumption G sensor to detect whether the equipment is in motion or...

Page 9: ...tion Guide 5 1 Installation diagram Battery Switch SIM card slot Red LED Fast blink GPRS connecting Slow Blink GPRS Connected Solid on Module error Light sensor E SIM Green LED Solid on Position Blink...

Page 10: ...rts to flash indicating that the terminal is powered on 5 2 3 Parameter setting TCP UDP connection mode setting For example the client s server IP is 119 145 40 64 port number 8881 If it is connected...

Page 11: ...on function A 1 LBS WIFI mode A 0 GPS position priority default A 3 Examples LBS 1 enter LBS WIFI position mode Switch off GPS 5 3 4 Clock mode Command Format WAKEUP T1 T2 T3 T4 Description Set a mult...

Page 12: ...e tracking T1 The return interval for entering the tracking mode during exercise the value range is 1 5 minutes T2 Return interval at rest value range 5 43200 minutes or alarm clock format HH MM A 1 Q...

Page 13: ...er alarm no track A 2 Open tamper alarm track 15 minutes every 300 seconds A 1 Close tamper alarm A 0 Open tamper alarm track 60 minutes every 60 seconds Default A 0 For example FALL 0 Open tamper ala...

Page 14: ...dby server IP as 119 23 233 52 Port as 6000 communication mode as TCP IP2 www 365qczx com 6000 0 Set standby server domain name as www 365qczx com port as 6000 communication mode UDP IP2 0 0 delete st...