• TESTING CONTINUITY USING TONE (SWITCH TO “TONE”):

   (CAUTION: DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V     

    IN THIS MODE.)

  

 1. Connect the test leads to the subject pair.

   2. Use a handset or headset at the remote end and touch the wire end(s) with the

        clip leads(s)

   3. Reception of tone is an indication of continuity

• MODULAR TESTING:

   1. All above tests are available through the modular plug for line 1 only - red and    

       green wires.

• COAX TESTING:

  

 1.

 

To test unterminated coax, connect red to outer shield and black to center

        conductor or red to outer shield and black to ground.

   2. To test terminated coax, connect red to connector housing and black to center

        pin or red to connector housing and black to ground.

• MAINTENANCE

   

BATTERY REPLACEMENT INSTRUCTIONS:

 

 1. Seperate the case, install a fresh 9V battery and reassemble.

       DO NOT OVERTIGHTEN.

  2. Warranty limited solely to repair or replacement; no warranty of

       merchantability, fitness for a particular purpose or consequential

      damages.

-4-

Summary of Contents for 365-00007

Page 1: ...Volume control for increased sensitivity and adjustable to suit work environment Recessed ON OFF button prevents battery drain Power supply is in any 9V battery with a life of approximately 100 hours A plug receptacle is provided for head set or head phone 1 3 position toggle switch Phone jack Tone Generator 3 colored LED Red and black test leads 4conductor modular cord and plug Tip Amplifier Prob...

Page 2: ...subject wire 5 The plug receptacle is provided for connecting to a head set or hand set MAINTENANCE The Amplifier Probe is maintenance free except for battery replacement Remove the screw from the battery compartment replace the 9V battery and reassemble Warranty limited solely to repair or replacement no warranty of merchantability fitness for a particular purpose or consequential damages FEATURE...

Page 3: ... the off position the indicator lamp will flicker YELLOW when the test leads are connected to the subject pair 4 If you switch the test set to CONT it will terminate the call on the subject line SENDING TONE SWTICH TO TONE CAUTION DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MODE 1 Connect the test leads to the pair or attach one lead to the ground and one lead to either side of th...

Page 4: ...ug for line 1 only red and green wires COAX TESTING 1 To test unterminated coax connect red to outer shield and black to center conductor or red to outer shield and black to ground 2 To test terminated coax connect red to connector housing and black to center pin or red to connector housing and black to ground MAINTENANCE BATTERY REPLACEMENT INSTRUCTIONS 1 Seperate the case install a fresh 9V batt...

Reviews: