INSTRUCTIONS:

• 

IDENTIFYING TIP & RING (SWITCH TO “OFF”):

   

1. Connect the RED test lead to the side of the one line and the BLACK lead to the     

        side of the another line.

   2. The LED will glow “GREEN” when you connect the RED test lead to the RING     

        SIDE of the line.

   3. The LED will glow “RED” when you connect the RED test lead to the TIP SIDE of    

        the line.

• 

IDENTIFYING LINE CONDITION (SWTICH TO “OFF):

   

1. Connect the RED test lead to the RING SIDE of the line and the BLACK to 

        the TIP.

   2. Watch the LED:

        1) A BRIGHT “GREEN” LED indicates a CLEAR line.

        2) NO lamp indicates a BUSY line.

        3) A BRIGHTLY FLICKERING “YELLOW”  lamp indicates a RINGING line.

• 

VERIFYING LINES ( SWITCH TO “OFF” THEN “CONT” ):

   1. Dial the line to be verified.

   2. While the line is ringing, connect the RED lead to the RING SIDE  of the line and

        the BLACK to the TIP.

   3. In the “off” position, the indicator lamp will flicker “YELLOW” when the test

        leads are connected to the subject pair

   4. If you switch the test set to “CONT”, it will terminate the call on the subject line.

• 

SENDING TONE (SWTICH TO “TONE”):

(CAUTION: DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V 
IN THIS MODE.)

    1. Connect the test leads to the pair, or attach one lead to the ground and one

         lead to either side of the line.

    2. A dual alternating tone, or single solid tone can be selected from the switch

         inside the tone generator.

    3. Probe the suspected wires with the amplifier probe. Reception of tone will be

         strongest on the subject wire. In cases of ready access to bare conductor,

         a handset may be used to receive the tone.

• TESTING CONTINUITY (SWITCHING TO “CONT”):

(CAUTION: DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V 

IN THIS MODE.)

    

1. Connect the test leads to the subject pair.

    2. Use “CONT” position.

    3. A bright “GREEN” light indicates continuity. The LED will not glow if the

         line resistance exceeds 10000 Ω

     

 

-3-

Summary of Contents for 365-00007

Page 1: ...Volume control for increased sensitivity and adjustable to suit work environment Recessed ON OFF button prevents battery drain Power supply is in any 9V battery with a life of approximately 100 hours A plug receptacle is provided for head set or head phone 1 3 position toggle switch Phone jack Tone Generator 3 colored LED Red and black test leads 4conductor modular cord and plug Tip Amplifier Prob...

Page 2: ...subject wire 5 The plug receptacle is provided for connecting to a head set or hand set MAINTENANCE The Amplifier Probe is maintenance free except for battery replacement Remove the screw from the battery compartment replace the 9V battery and reassemble Warranty limited solely to repair or replacement no warranty of merchantability fitness for a particular purpose or consequential damages FEATURE...

Page 3: ... the off position the indicator lamp will flicker YELLOW when the test leads are connected to the subject pair 4 If you switch the test set to CONT it will terminate the call on the subject line SENDING TONE SWTICH TO TONE CAUTION DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MODE 1 Connect the test leads to the pair or attach one lead to the ground and one lead to either side of th...

Page 4: ...ug for line 1 only red and green wires COAX TESTING 1 To test unterminated coax connect red to outer shield and black to center conductor or red to outer shield and black to ground 2 To test terminated coax connect red to connector housing and black to center pin or red to connector housing and black to ground MAINTENANCE BATTERY REPLACEMENT INSTRUCTIONS 1 Seperate the case install a fresh 9V batt...

Reviews: