RND 320-KEL Series User Manual Download Page 6

10

11

RND  320-KEL Series

RND  320-KEL Series

4. The Storage Function of Steady State and Recalling

   

  Note: The load can save and recall 100 sets of stationary setting values.     

     And to set the values, the number keys, knob and up & down buttons all  

     can be used.

 

     4.1 Storage function

Operation Method: Taking 10.000V stored to 99 as example.

4.2 Recall Function

      

  Operation method: taking recalling the stored steady-state value in 99  

        As example.

5.  Ml-MS Fast Recall and Storage Function

     

 

5.1 Ml-MS Fast Recall Function

 

   Note: By pressing Ml-MS, the steady state content stored in Ml-MS  

 

   can be quickly recalled. 

 

     

 5.2 Ml-MS Fast Storage Function

 

  Note: You can change the content of Ml-MS by selecting Ml-MS 

 

  button; and then press the currently selected Ml-MS button to fast  

   

  save the value to the currently selected M key. 

 

 

  For example, the previous content of Ml is CV+15.001V and now  

 

             needing to modify as CV+14.000V, you can press Ml to recall the  

 

 

  content and then modify to 14.000V through rotating the knob and  

  

  then pressing the number keys to select the value you want. After    

   

  that, press Ml again to save it in Ml.

6. Short Circuit Function

     Note: the load will make the tested equipment output the max current.  

     Operation Method:

7. Dynamic Test Function

  

   Note: There are 6 setting functions in this mode: Dynamic CV, Dynamic CC,  

     Dynamic CR, Dynamic CW, Dynamic Pulse and Dynamic Flip. And this mode  

     has no storage function, so it can be only set first and then run.

 

     7.1 Dynamic CV, Dynamic CR, & Dynamic CW

 

 Description: used for the different duty cycle output of 2 different volt 

 

 ages at a certain frequency. 

 

 

 Operation Method: 

 

 

 Taking the first voltage lV, the second voltage 2V , the cycle frequency  

 

 lHZ and the duty cycle 40% as example; as for Dynamic CR and 

 

 Dynamic CW, just need to change the setting voltage into resistance or  

            power. And Dynamic CR selects mode 3 while Dynamic CW 

            selects mode 4.

Summary of Contents for 320-KEL Series

Page 1: ...1 RND 320 KEL Series USER MANUAL BEDIENUNGSANLEITUNG ANV NDARMANUAL RND 320 KEL Series...

Page 2: ...ERVIEW 5 Introduction 5 Main Features 5 Front Panel Overview 6 OPERATION 6 Keyboard Operation 6 Setting the Max Value of Load 7 Steady State 8 The Storage of Steady State and Recalling 10 Ml MS Fast R...

Page 3: ...ct the power cord before fuse replacement Make sure the cause of fuse blow out is fixed before fuse replacement Introduction RND KEL series 150W 300W single channel programmable DC electronic loads ar...

Page 4: ...e adjusted and will flash 6 Entering numbers 7 Constant Current Mode Button 8 Constant Voltage Mode Button 9 Constant Power Mode Button 10 Constant Resistance Mode Button 11 Confirmation Button 12 On...

Page 5: ...rd to enter constant voltage operation mode 2 Setting the desired constant voltage through the keyboard 3 Turn on the ON OFF button to start the electronic load Load Voltage 3 3 Constant Resistance Op...

Page 6: ...ent of Ml is CV 15 001V and now needing to modify as CV 14 000V you can press Ml to recall the content and then modify to 14 000V through rotating the knob and then pressing the number keys to select...

Page 7: ...7 2 Dynamic CC Note used for the different duty cycle output of 2 different currents at a certain frequency Operation Method taking it as example that the change slope of the first current is 0 00lA...

Page 8: ...ity and time it tests the battery And the test will be turned off automatically once it meets any one of the conditions Operation Description taking it as example that the setting is saved in group 1...

Page 9: ...ht bottom is the count of triggers 8 Sequential Operation Function 8 1 Sequential Setting Function Note It can save 7 groups at most and every set it can at most set 84 dynamic currents And the set cu...

Page 10: ...d use it 9 Battery Test Function 9 1 The Setting Function of the Battery Test Note It can at most set 10 groups of battery test parameters According to the set current voltage capacity and time it tes...

Page 11: ...t bottom is the running time and the LED display on the right bottom is the consumption of capacity 10 OCP Test Function Note when the voltage reaches the VON value it will delay for some time and the...

Page 12: ...e step reduction value is 0 1A the reduction time is ls the ending current is lA OCP voltage is 8V the maximum current is 1 9A and the minimum current is 1 1A Remarks press ON OFF to start and then th...

Page 13: ...se progressively until it reaches the cut off power or the voltage is higher than that set by OPP and then the output ends After that if the voltage is higher than the OPP voltage and meanwhile the po...

Page 14: ...000A 0V P0106 0 0000V 0 0000A 0V P0107 0 0000V 0 0000A 0V P0108 0 0000V 0 0000A 0V P0109 0 0000V 0 0000A 0V P0110 0 0000V 0 0000A 0V P0110 Return to the steady state mode Remarks During the operation...

Page 15: ...tton 3 is valid There will be no memory function 15 Baud Rate Setting Function Note Manually modify the baud rate Operation Description changing the baud rate 57600 to 115200 as example Remarks please...

Page 16: ...L Series Specifications Note The specifications below are tested under the conditions of temperature 25 C 5 C and the warm up for 20 minutes MODELS RND 320 KEL102 RND 320 KEL103 Note Specifications ar...

Page 17: ...32 RND 320 KEL Series Distrelec Group AG Grabenstrasse 6 CH 8606 N nikon www distrelec de...

Reviews: