Page 2: ...ERVIEW 5 Introduction 5 Main Features 5 Front Panel Overview 6 OPERATION 6 Keyboard Operation 6 Setting the Max Value of Load 7 Steady State 8 The Storage of Steady State and Recalling 10 Ml MS Fast R...

Page 3: ...ct the power cord before fuse replacement Make sure the cause of fuse blow out is fixed before fuse replacement Introduction RND KEL series 150W 300W single channel programmable DC electronic loads ar...

Page 4: ...e adjusted and will flash 6 Entering numbers 7 Constant Current Mode Button 8 Constant Voltage Mode Button 9 Constant Power Mode Button 10 Constant Resistance Mode Button 11 Confirmation Button 12 On...

Page 5: ...rd to enter constant voltage operation mode 2 Setting the desired constant voltage through the keyboard 3 Turn on the ON OFF button to start the electronic load Load Voltage 3 3 Constant Resistance Op...

Page 6: ...ent of Ml is CV 15 001V and now needing to modify as CV 14 000V you can press Ml to recall the content and then modify to 14 000V through rotating the knob and then pressing the number keys to select...

Page 7: ...7 2 Dynamic CC Note used for the different duty cycle output of 2 different currents at a certain frequency Operation Method taking it as example that the change slope of the first current is 0 00lA...

Page 8: ...ity and time it tests the battery And the test will be turned off automatically once it meets any one of the conditions Operation Description taking it as example that the setting is saved in group 1...

Page 9: ...ht bottom is the count of triggers 8 Sequential Operation Function 8 1 Sequential Setting Function Note It can save 7 groups at most and every set it can at most set 84 dynamic currents And the set cu...

Page 10: ...d use it 9 Battery Test Function 9 1 The Setting Function of the Battery Test Note It can at most set 10 groups of battery test parameters According to the set current voltage capacity and time it tes...

Page 11: ...t bottom is the running time and the LED display on the right bottom is the consumption of capacity 10 OCP Test Function Note when the voltage reaches the VON value it will delay for some time and the...

Page 12: ...e step reduction value is 0 1A the reduction time is ls the ending current is lA OCP voltage is 8V the maximum current is 1 9A and the minimum current is 1 1A Remarks press ON OFF to start and then th...

Page 13: ...se progressively until it reaches the cut off power or the voltage is higher than that set by OPP and then the output ends After that if the voltage is higher than the OPP voltage and meanwhile the po...

Page 14: ...000A 0V P0106 0 0000V 0 0000A 0V P0107 0 0000V 0 0000A 0V P0108 0 0000V 0 0000A 0V P0109 0 0000V 0 0000A 0V P0110 0 0000V 0 0000A 0V P0110 Return to the steady state mode Remarks During the operation...

Page 15: ...tton 3 is valid There will be no memory function 15 Baud Rate Setting Function Note Manually modify the baud rate Operation Description changing the baud rate 57600 to 115200 as example Remarks please...

Page 16: ...L Series Specifications Note The specifications below are tested under the conditions of temperature 25 C 5 C and the warm up for 20 minutes MODELS RND 320 KEL102 RND 320 KEL103 Note Specifications ar...

Page 17: ...32 RND 320 KEL Series Distrelec Group AG Grabenstrasse 6 CH 8606 N nikon www distrelec de...