After removing the tip, blow out any oxide dust that may have formed in the tip retaining area of the
barrel. Be careful to avoid getting this dust in your eyes. Replace the tip and screw back the knurled nut
barrel assembly using only firm hand pressure to tighten. Pliers should only be used to tighten the nut to
avoid burning your fingers, but care should be taken not to over-tighten as this could damage the element.
GENERAL CLEANING
The outer cover of the iron and station may be cleaned with a damp cloth using small amounts of liquid
detergent. Never submerse the unit in liquid or allow any liquid to enter the case of the station. Never use
any solvent to clean the case.
IMPORTANT SERVICE NOTE:
There are no user serviceable parts inside the unit. Do not open the unit. If the fuse blows, only replace with
an equivalent fuse. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure they do not play with the appliance.
If the iron or station should become faulty or, for some reason not operate normally, the system should be
returned to the service department of your authorized dealer or service agent, or a similarly qualified
person, in order to avoid a hazard.