Rhein-Nadel Automation GmbH
9
14.04.2014
VT-BA ESK2002-GB
4.4
Description of the Individual Codes for Programming the Control Unit
KANAL l
KANAL 2
CODE
Settings for channel 1
The following functions can be set or limited for channel 1 in this submenu:
- vibration amplitude - signal direction of the remote control
- remote control - soft start time and soft stop time
KANAL l
KANAL 2
CODE
Settings for channel 2
The following functions can be set or limited for channel 2 in this submenu:
- vibration amplitude - signal direction of the remote control
- remote control - soft start time and soft stop time
- selection Vibrationhopper or Belthopper with 1-phase motor
KANAL l
KANAL 2
CODE
Settings for channel 3
The following functions can be set or limited for channel 3 in this submenu:
- vibration amplitude - signal direction of the remote control
- remote control - soft start time and soft stop time
- selection Vibrationhopper or Belthopper with 1-phase motor
KANAL l
KANAL 2
CODE
Lock setpoint
This submenu allows the setpoints (vibration amplitude) to be blocked in the main menu. The
setpoints for channel 1, channel 2 and channel 3 can no longer be changed in the main menu.
This prevents the output values being accidentally changed. Changes can only be made using
code C001, code C002 and C012.
KANAL l
KANAL 2
CODE
Setting sensor input 1
Sensor input 1 is activated in this submenu. The following functions can also be set.
- invert input signal direction - time before switch-on
- time before switch-off
KANAL l
KANAL 2
CODE
Setting sensor input 2
Sensor input 2 is activated in this submenu. The following functions can also be set.
- invert input signal direction - time before switch-on
- time before switch-off
KANAL l
KANAL 2
CODE
Selecting the sensor links
The sensors activated with codes C004 and C005 can be linked to each other in this submenu.
KANAL l
KANAL 2
CODE
Setting the cycle control
Set the sensor input to be monitored and how the control will react when there is a fault.
KANAL l
KANAL 2
CODE
Display status
This submenu is used to check the set vibration frequency and the sensor inputs.
KANAL l
KANAL 2
CODE
To call software version
Determinat. 411. 59. 10. 23.11.99
date
version -no.
type
internal no.
type:
59 = ESK 2001
58 = ESG 2001
57 = ESK 2000
56 = ESG 2000
KANAL l
KANAL 2
CODE
Output preset with an external voltage
KANAL l
KANAL 2
CODE
Store parameters
If the values (user parameters) previously set in the different submenus are to be stored, call
this submenu.
KANAL l
KANAL 2
CODE
Block all setting functions
This code blocks all entry options on the control unit. The values can no longer be changed.
The menu can now only be enabled using this code.
KANAL l
KANAL 2
CODE
Reset parameters
This submenu allows the user to reset the control unit to the factory settings. If user parameters
have been stored, the control unit can also be set to these settings.