Rhein-Nadel Automation GmbH
8
14.04.2014
VT-BA ESK2002-GB
4.2
Switching on the Control Unit
Switch on the control unit with the mains power switch. The main menu will appear in the display showing the last set-
point set in channel 1 (bowl feeder feed rate).
KANAL l
KANAL 2
CODE
The following displays may also appear depending on the circuit state of the unit.
KANAL l
KANAL 2
CODE
The remote control has been activated but is currently not available on the unit.
(middle priority)
KANAL l
KANAL 2
CODE
The unit has been switched off with the upper left-hand key on the membrane keyboard, all
functions are blocked.
(high priority)
KANAL l
KANAL 2
CODE
The back pressure control sensor has been assigned thus switching off channel 1 (bowl
feeder).(low priority)
4.3
Main Menu/Setting and Displaying Setpoints for Channel 1, Channel 2 and Channel 3
Display of setpoint or the channel 1
output (vibratory feeder)
Alternatively: STOP, OFF or BACK
PRESSURE
(see above)
KANAL l
KANAL 2
CODE
No entries possible
Enter code to change or make re-
quired settings.
KANAL l
KANAL 2
CODE
Enter code.
See section 4.4 for de-
scription of code.
Setpoint preset for channel 1
(bowl feeder)
KANAL l
KANAL 2
CODE
Entry in %; return to
display mode to store
Setpoint preset for channel 2
(vibrationunit or 1-phase motor)
KANAL l
KANAL 2
CODE
Entry in %; return to
display mode to store
Setpoint preset for channel 3
(vibrationunit or 1-phase motor)
KANAL l
CODE
KANAL 2
Entry in %; return to
display mode to store
From these four basic displays you can page through the main menu using the cursor keys (UP/DOWN). Press the
ENTER key in the main menu to activate a menu item for setting or adjustment. The decimal point will flash once you
have pressed the ENTER key. Changes can now be made using the cursor keys (UP/DOWN). Confirm the entries by
pressing the ENTER key again. The decimal point will no longer flash. You can scroll further through the menu using
the cursor keys. This procedure is also used in the code menus described below.
All displays shown in the following section represent the factory settings. If the actual display on the control unit differs,
the factory setting has been changed in the individual codes for a specific application.