![RME Audio Hammerfall DIGI9652 User Manual Download Page 18](http://html1.mh-extra.com/html/rme-audio/hammerfall-digi9652/hammerfall-digi9652_user-manual_1467334018.webp)
DIGI9652
User’s Guide
© RME
18
Crackle during record or playback:
•
Increase the number and size of buffers in the ‘Settings’ dialog or in the application.
•
Try different cables (coaxial or optical) to rule out any defects here.
•
Check that cables/devices have not been connected in a closed loop. If so, set the card’s
clock mode to ‘Master’.
•
Increase the buffer size of the hard disk cache.
32 kHz files will not play back:
•
Hammerfall
does not have an internal 32 kHz clock, as this frequency is not covered by
the ADAT standard. However, you can record and playback via S/PDIF if the card is clocked
from an external device i.e. AutoSync or Word Clock are active, and fed S/PDIF or
equivalent word clock signal is 32 kHz.
17. TECH INFO
See http://www.rme-audio.com/techinfo/index.htm or the directory
\rmeaudio.web\techinfo
on
the RME Driver CD for more detailed information. At the time of writing, the following
Tech Info
is available:
Synchronization II (DIGI96 series)
Digital audio synchronization - technical background and pitfalls.
Information on driver updates
Lists all changes in the drivers of the Hammerfall series.
ADI-1 Inside
Technical information about the RME ADI-1 (20-bit AD/DA converter).
ADI-8 Inside
Technical information about the RME ADI-8 (24-bit AD/DA converter).
TMS (Track Marker Support)
Description of the TMS technology to transfer CD- and DAT information.