52
User’s Guide DMC-842
© RME
21. MIDI Implementation DMC-842
21.1 Basic SysEx Format
Value Name
F0h SysEx
header
00h 20h 0Dh
MIDITEMP manufacturer ID
42h
Model ID (DMC-842)
00h..77h, 7Fh
Bank number / device ID (7Fh = broadcast, all IDs)
mm Message
type
nn
Parameter number (see table 1)
oo Databyte
F7h EOX
Bank Number / Device ID
The lower nibble refers to the device ID (0..7), the higher nibble refers to the bank number
(0..7), e. g. 25h means bank 2, device 5. 7Fh adresses all banks and all devices.
21.2 Message Types
Value Name
10h
Request interface value
11h
Request level meter data
12h
Request microphone data (replaced by separate values for each channel)
40h
Request microphone data input 1
41h
Request microphone data input 2
42h
Request microphone data input 3
43h
Request microphone data input 4
44h
Request microphone data input 5
45h
Request microphone data input 6
46h
Request microphone data input 7
47h
Request microphone data input 8
20h
Set interface value
22h
Set microphone value
30h
Interface value response
31h
Level meter data response
32h
Microphone data response
Request Interface Value
Format: F0 00 20 0D 42 (bank no. / dev ID) 10 F7
This string triggers a complete dump of all interface value response data bytes.
Interface Value Response
After being triggered by receiving a request value command, device sends a string of all value
response data bytes. Message type is set to 30h.
Set Interface Value
Sets any number of parameters.
nn / oo can be repeated freely.
Summary of Contents for DMC-842
Page 5: ...User s Guide DMC 842 RME 5 User s Guide DMC 842 General...
Page 12: ...12 User s Guide DMC 842 RME...
Page 13: ...User s Guide DMC 842 RME 13 User s Guide DMC 842 Usage and Operation...
Page 29: ...User s Guide DMC 842 RME 29 User s Guide DMC 842 Inputs and Outputs...
Page 39: ...User s Guide DMC 842 RME 39 User s Guide DMC 842 Technical Reference...