background image

General Specifications

Standards

IEEE-80, IEEE-367, IEEE-1590, IEEE-1615, Motorola R56, BR 876-310-100 BT 
(Telcordia), Bellcore SR-3966,  IEEE 802.3, IEEE 802.1Q (VLAN), ITU-T V.24, ROHS

IEEE-80, IEEE-367, IEEE-1590, IEEE-1615, Motorola R56, BR 876-310-100 BT 
(Telcordia), Bellcore SR-3966,  IEEE 802.3, IEEE 802.1Q (VLAN), ITU-T V.24, ROHS

IEEE-80, IEEE-367, IEEE-1590, IEEE-1615, Motorola R56, BR 876-310-100 BT 
(Telcordia), Bellcore SR-3966,  IEEE 802.3, IEEE 802.1Q (VLAN), ITU-T V.24, ROHS

IEEE-80, IEEE-367, IEEE-1590, IEEE-1615, Motorola R56, BR 876-310-100 BT 
(Telcordia), Bellcore SR-3966,  IEEE 802.3, IEEE 802.1Q (VLAN), ITU-T V.24, ROHS

IEEE-80, IEEE-367, IEEE-1590, IEEE-1615, Motorola R56, BR 876-310-100 BT 
(Telcordia), Bellcore SR-3966,  IEEE 802.3, IEEE 802.1Q (VLAN), ITU-T V.24, ROHS

IEEE-80, IEEE-367, IEEE-1590, IEEE-1615, Motorola R56, BR 876-310-100 BT 
(Telcordia), Bellcore SR-3966,  IEEE 802.3, IEEE 802.1Q (VLAN), ITU-T V.24, ROHS

Transmission method

Frequency modulated light via two optical fibers

Frequency modulated light via two optical fibers

Frequency modulated light via two optical fibers

Frequency modulated light via two optical fibers

Frequency modulated light via two optical fibers

*Dual and Bi-Directional 
 Fiber accepted

Transmission method

Multimode: 850nm/1310nm

Multimode: 850nm/1310nm

Multimode: 850nm/1310nm

Multimode: 850nm/1310nm

Multimode: 850nm/1310nm

*Dual and Bi-Directional 
 Fiber accepted

Transmission method

Single-mode: 1310nm/1550nm

Single-mode: 1310nm/1550nm

Single-mode: 1310nm/1550nm

Single-mode: 1310nm/1550nm

Single-mode: 1310nm/1550nm

*Dual and Bi-Directional 
 Fiber accepted

Maximum Fiber
Attenuation / Distance

Multimode (62.5/125µm)

Multimode (62.5/125µm)

2km/1.25 miles

2km/1.25 miles

2km/1.25 miles

2km/1.25 miles

Maximum Fiber
Attenuation / Distance

Multimode (50/125µm)

Multimode (50/125µm)

2km/1.25 miles

2km/1.25 miles

2km/1.25 miles

2km/1.25 miles

Maximum Fiber
Attenuation / Distance

Single-mode (9/125µm)

Single-mode (9/125µm)

20km/12.4 miles; 40km/24.9 miles; 60km/37 miles;
120km/74 miles

20km/12.4 miles; 40km/24.9 miles; 60km/37 miles;
120km/74 miles

20km/12.4 miles; 40km/24.9 miles; 60km/37 miles;
120km/74 miles

20km/12.4 miles; 40km/24.9 miles; 60km/37 miles;
120km/74 miles

Fiber Type

ST, SC or FC connectors

ST, SC or FC connectors

ST, SC or FC connectors

ST, SC or FC connectors

ST, SC or FC connectors

ST, SC or FC connectors

Fiber Type

Multimode: 62.5/125µm, and 50/125µm

Multimode: 62.5/125µm, and 50/125µm

Multimode: 62.5/125µm, and 50/125µm

Multimode: 62.5/125µm, and 50/125µm

Multimode: 62.5/125µm, and 50/125µm

Multimode: 62.5/125µm, and 50/125µm

Fiber Type

Single-mode: 8-9/125µm

Single-mode: 8-9/125µm

Single-mode: 8-9/125µm

Single-mode: 8-9/125µm

Single-mode: 8-9/125µm

Single-mode: 8-9/125µm

Storing Temperature

-40˚C to +70˚C (-40˚F to +158˚F)

-40˚C to +70˚C (-40˚F to +158˚F)

-40˚C to +70˚C (-40˚F to +158˚F)

-40˚C to +70˚C (-40˚F to +158˚F)

-40˚C to +70˚C (-40˚F to +158˚F)

-40˚C to +70˚C (-40˚F to +158˚F)

Operating Temperature

0˚C to 50˚C (0˚F to 122˚F)

0˚C to 50˚C (0˚F to 122˚F)

0˚C to 50˚C (0˚F to 122˚F)

0˚C to 50˚C (0˚F to 122˚F)

0˚C to 50˚C (0˚F to 122˚F)

0˚C to 50˚C (0˚F to 122˚F)

Humidity

95% non-condensing

95% non-condensing

95% non-condensing

95% non-condensing

95% non-condensing

95% non-condensing

BER

<10

-9

<10

-9

<10

-9

<10

-9

<10

-9

<10

-9

Dimensions

W 19in. x D 10in. x H 1.7 (1RU)  (W 485mm x D 250mm x H 43mm)

W 19in. x D 10in. x H 1.7 (1RU)  (W 485mm x D 250mm x H 43mm)

W 19in. x D 10in. x H 1.7 (1RU)  (W 485mm x D 250mm x H 43mm)

W 19in. x D 10in. x H 1.7 (1RU)  (W 485mm x D 250mm x H 43mm)

W 19in. x D 10in. x H 1.7 (1RU)  (W 485mm x D 250mm x H 43mm)

W 19in. x D 10in. x H 1.7 (1RU)  (W 485mm x D 250mm x H 43mm)

Ethernet

10/100M, full/duplex, auto negotiation

10/100M, full/duplex, auto negotiation

10/100M, full/duplex, auto negotiation

10/100M, full/duplex, auto negotiation

10/100M, full/duplex, auto negotiation

10/100M, full/duplex, auto negotiation

Protocol

IEEE 802.3, IEEE 802.1Q (VLAN)

IEEE 802.3, IEEE 802.1Q (VLAN)

IEEE 802.3, IEEE 802.1Q (VLAN)

IEEE 802.3, IEEE 802.1Q (VLAN)

IEEE 802.3, IEEE 802.1Q (VLAN)

IEEE 802.3, IEEE 802.1Q (VLAN)

MAC Address Entries

4096

4096

4096

4096

4096

4096

Ethernet Connector

RJ-45

RJ-45

RJ-45

RJ-45

RJ-45

RJ-45

RS-232/422/485 Data Port

ITU-T V.24 Standard

ITU-T V.24 Standard

ITU-T V.24 Standard

ITU-T V.24 Standard

Data Rate

9600Kbps (Asynchronous)

9600Kbps (Asynchronous)

9600Kbps (Asynchronous)

9600Kbps (Asynchronous)

Connector

RJ-45

RJ-45

RJ-45

RJ-45

E&M/Analog Data Ports

2/4 Wire E&M, 4 Wire Analog Data, 2/4 Wire Analog Data

2/4 Wire E&M, 4 Wire Analog Data, 2/4 Wire Analog Data

2/4 Wire E&M, 4 Wire Analog Data, 2/4 Wire Analog Data

2/4 Wire E&M, 4 Wire Analog Data, 2/4 Wire Analog Data

2/4 Wire E&M, 4 Wire Analog Data, 2/4 Wire Analog Data

2/4 Wire E&M, 4 Wire Analog Data, 2/4 Wire Analog Data

E Wire Index

Max. electric current

Max. electric current

22mA

22mA

22mA

22mA

E Wire Index

Saturation voltage

Saturation voltage

3V

3V

3V

3V

E Wire Index

Dial speed

Dial speed

>20pps

>20pps

>20pps

>20pps

M Wire Index

Constant current

Constant current

7mA

7mA

7mA

7mA

M Wire Index

Min. detecting current

Min. detecting current

5mA

5mA

5mA

5mA

M Wire Index

Pulse dial identify

Pulse dial identify

>20pps

>20pps

>20pps

>20pps

Bandwidth

300Hz ~ 3.4KHz

300Hz ~ 3.4KHz

300Hz ~ 3.4KHz

300Hz ~ 3.4KHz

300Hz ~ 3.4KHz

300Hz ~ 3.4KHz

Connector

RJ-45

RJ-45

RJ-45

RJ-45

RJ-45

RJ-45

Impedance

600 Ohm

600 Ohm

600 Ohm

600 Ohm

600 Ohm

600 Ohm

Longitudinal Conversion Loss

>60dB

>60dB

>60dB

>60dB

>60dB

>60dB

Return Loss

>30dB

>30dB

>30dB

>30dB

>30dB

>30dB

Idle Channel Noise

75dB

75dB

75dB

75dB

75dB

75dB

CMRR

>60dB

>60dB

>60dB

>60dB

>60dB

>60dB

Insertion Loss

0dB ± 0.5dB each direction

0dB ± 0.5dB each direction

0dB ± 0.5dB each direction

0dB ± 0.5dB each direction

0dB ± 0.5dB each direction

0dB ± 0.5dB each direction

Overload Level

8dBm into 600 Ohms

8dBm into 600 Ohms

8dBm into 600 Ohms

8dBm into 600 Ohms

8dBm into 600 Ohms

8dBm into 600 Ohms

Redundant Powering

12VDC, 24VDC, 48VDC and/or 115/240VAC local power

12VDC, 24VDC, 48VDC and/or 115/240VAC local power

12VDC, 24VDC, 48VDC and/or 115/240VAC local power

12VDC, 24VDC, 48VDC and/or 115/240VAC local power

12VDC, 24VDC, 48VDC and/or 115/240VAC local power

12VDC, 24VDC, 48VDC and/or 115/240VAC local power

Redundant Powering

Built-In

48VDC

48VDC

(36 ~72VDC)

(36 ~72VDC)

(36 ~72VDC)

Redundant Powering

Adapter

24VDC

24VDC

(18 ~ 36VDC)

(18 ~ 36VDC)

(18 ~ 36VDC)

Redundant Powering

Adapter

12VDC 

12VDC 

(9 ~ 18VDC)

(9 ~ 18VDC)

(9 ~ 18VDC)

Redundant Powering

Adapter

115/240VAC

115/240VAC (90 ~260VAC) Compatible with 127 ~ 370VDC

(90 ~260VAC) Compatible with 127 ~ 370VDC

(90 ~260VAC) Compatible with 127 ~ 370VDC

Input Current

0.25A

0.25A

0.25A

0.25A

0.25A

0.25A

Max Power Consumption

20W

20W

20W

20W

20W

20W

Page 12

   

 

RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

Summary of Contents for RLH-PM-3 Series

Page 1: ...x auto negotiation Each voice channel is connected to a single RJ 45 using pins 4 5 and RJ 11 adapter cables are provided Supports call forwarding Available with ST SC or FC connectors Optional ring down circuit over analog phone is available Includes one RS 232 or RS 422 485 port Available in Single or Multi mode fiber up to 120km fiber range EIA 19 1RU rack mountable Convenient front panel LED s...

Page 2: ...igh DC voltages Use caution when handling copper wiring The chassis must be grounded using the ground lug to reduce the risk of damage from lightning Warning The intra building port s of the equipment or subassembly is suitable for connection to intrabuilding or unexposed wiring or cabling only The intra building port s of the equipment MUST NOT be metallically connected to interfaces that connect...

Page 3: ...mage Check the contents to ensure correct model and powering options Make sure you have the correct fiber type and power available Have a clean dry installation environment ready Required to install Install the POTS Mux System into a 19 equipment rack or other suitable location Check the polarity and voltage of the power with a multimeter before connecting to avoid damage Connect fiber cables to c...

Page 4: ...undant powering options include 115 240VAC and or 12VDC 24VDC or 48VDC local power Note The DC power terminals are polarity sensitive Observe the and terminals on the DC input terminal Note FXS Sub units are electrically different from FXO CO units and cannot be interchanged Once all connections are checked turn the unit ON using the power switch on the front panel Note The FXO and FXS units norma...

Page 5: ...hone system Ringdown Circuit Applications Diagram Daisy Chain Application Add services at drop points by daisy chaining POTS Mux units together FXO CO and FXS Sub system pairs may be interconnected using copper wiring for the functions that are being extended Fiber Fiber POTS MUX POTS MUX POTS MUX POTS MUX FXS SUB FXO CO FXS SUB FXO CO Analog Phone Data 10 100M Ethernet RS 232 422 485 Data Multipl...

Page 6: ...er System front panel contains analog phone and E M data channel activity indicator LED s along with a power LED and switch The RJ 45 Ports on the front are the four 10 100 Ethernet ports and the two RS 232 or RS 422 485 channels POTS Mux 16 Channel System Front Panel LED status display The yellow PHONE LEDs on the front panel indicated which analog phone POTS lines are being actively used E M Ana...

Page 7: ... RS 232 422 485 Data Application Diagram DB 9 Adapter Cable PIN 1 PIN 8 CH2 CH1 RJ 45 Female Pin Description RJ 45 Female Pin Description CH 1 CH 2 1 NC 5 NC 2 TXD Output 6 TXD Output 3 RXD Input 7 RXD Input 4 GND 8 GND DB 9 Female Pin Description DB 9 Female Pin Description 1 NC 6 NC 2 RX 7 NC 3 TX 8 NC 4 NC 9 NC 5 GND 5 GND 1 5 9 6 RS 232 Pin Description Charts RLH Industries Inc Tel 866 DO FIBE...

Page 8: ...nections are checked and power is applied turn the unit ON using the power switch on the front panel Note The DC power terminals are polarity sensitive Observe the and terminals on the DC input terminal Optical Ports The optical ports may be equipped with ST SC or FC fiber connectors A fiber pair is required for operation with dual fiber models TX is the signal output side and RX is the signal inp...

Page 9: ...on diagram for 2 4 wire Analog Audio and 4 wire Analog Data Pin Description Pin Description 1 NC 5 2 4 Wire Output 2 4 Wire Input 6 NC 3 4 Wire Input 7 NC 4 2 4 Wire Output 8 NC PIN 8 PIN 1 2 4W Analog Data 4W Analog Audio RJ 45 Pin Chart Troubleshooting If trouble is encountered verify all copper and fiber connections Refer to the LED Indicators on of the unit They show availability of power mode...

Page 10: ...ters provided All models include RJ 11 breakout adapter cables for easy connection to existing POTS lines One RJ 45 to DB 9 break out cable is included when applicable for easy connection to existing RS 232 or RS422 485 data lines E M models are compatible with 2 4 wire E M 2 4 wire Analog Data 2 4 wire Analog Audio Please contact your RLH sales representative for pricing and delivery information ...

Page 11: ... 61 62 63 64 65 Multimode Single Mode SC Connector 2km 1 25 mi range 20km 12 4 mi range 40km 24 9 mi range 60km 37 mi range ST Connector Single Fiber Bi Directional Dual Fiber 120km 74 mi range FC Connector Tx1310nm Rx1550nm Tx1550nm Rx1310nm 1310nm 1550nm 850nm 0 5km 0 3 mi range RLH Industries Inc Tel 866 DO FIBER Fax 714 532 1885 www fiberopticlink com Page 11 ...

Page 12: ...s W 19in x D 10in x H 1 7 1RU W 485mm x D 250mm x H 43mm W 19in x D 10in x H 1 7 1RU W 485mm x D 250mm x H 43mm W 19in x D 10in x H 1 7 1RU W 485mm x D 250mm x H 43mm W 19in x D 10in x H 1 7 1RU W 485mm x D 250mm x H 43mm W 19in x D 10in x H 1 7 1RU W 485mm x D 250mm x H 43mm W 19in x D 10in x H 1 7 1RU W 485mm x D 250mm x H 43mm Ethernet 10 100M full duplex auto negotiation 10 100M full duplex au...

Page 13: ...have been abused or mishandled where unauthorized repairs have been attempted or performed or the product has been damaged as a result of a natural disaster Compare this warranty to our competitors and see how our warranty will reduce your costs and simplify your maintenance activities To make a warranty claim or schedule repair or replacement of your RLH product please contact us for an RMA numbe...

Page 14: ...14 532 1885 www fiberopticlink com RLH Industries Inc 936 N Main Street Orange CA 92867 USA T 714 532 1672 F 714 532 1885 Please contact your RLH sales representative for pricing and delivery information Specifications subject to change without notice ...