background image

RJ-45 pin list

 

 

Connect 4 wire data pairs 

The analog voice-frequency data transmission supports constant transmission of 300Hz to 3400Hz. 
Connect the TX pairs of the interfacing equipment to pins (3 & 6) of RLH fiber link and the RX pairs of the 
interfacing equipment to pins (4 & 5) of RLH fiber link. The TX pairs on each unit of RLH fiber link 
corresponds to the RX pair at the other end.

 

 

Connect E&M leads 

Connect the E&M leads to the E&M INPUT and E&M OUTPUT RJ-45 pins as illustrated below. The 
RECEIVE of one side corresponds to the SEND at the other end. The E&M input is activated by 24VDC, 
and can accept up to 48VDC.  

"

 

E&M operational status may be determined from the 2 status LED’s located on the upper and lower ends 
of the RJ-45 Socket. The upper LED is ON when the input is active, and OFF when no input is present. 
The lower LED is ON when the E&M output is closed, and OFF when the output is open.  

RJ-45 Pin Chart

E&M INPUT

1

Signal Battery, SB

2

M-Lead

4 WIRE RX (Ring)

3

Ring, Audio Input, R

4 WIRE TX (Ring)

4

Ring, Audio Output, R1

4 WIRE TX (Tip)

5

Tip, Audio Output, T1

4 WIRE RX (Tip)

6

Tip, Audio Input, T

E&M OUTPUT

7

E-Lead

8

Signal Ground, SG

RJ-45

1

8

6

3

3
4
5
6

Ring, Audio Input, R
Ring, Audio Output, R1
Tip, Audio Output, T1
Tip, Audio Input, T

RJ-45 

Customer Equipment

RJ-45 

RLH Fiber Link

35 OHMS

NO Relay 

RJ-45

PINS

Contact

SEND INPUT

7

8

1

2

RECEIVE OUTPUT

SEND INPUT

RECEIVE OUTPUT

FIBERS

35 OHMS

NO Relay 

RJ-45

PINS

Contact

7

8

1

2

RLH 4 Wire E&M

RLH 4 Wire E&M

 

RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

 

Page 

"

6

Summary of Contents for 2 Channel 4 Wire Data with E&M and I/O

Page 1: ...and made in the U S A and covered by our Limited Lifetime Warranty Key Features Hardened to operate in 40 F to 158 F 40 C to 70 C System power options 24 48VDC and 125 VDC Multimode or single mode fi...

Page 2: ...ng connections to this device Guidelines for handling terminated fiber cable Do not bend fiber cable sharply Use gradual and smooth bends to avoid damaging glass fiber Keep dust caps on fiber optic co...

Page 3: ...y using fiber optic cable the DIN Fiber Link system provides absolute electrical isolation Application Diagrams The diagram below shows a typical configuration of the 4 Wire Data with E M and I O syst...

Page 4: ...VDC or 125VDC depending on model Flat head screwdriver for connection wiring Phillips screwdriver for attaching to wall optional Physical layout POWER FIBER FIBER LINK INPUT OUTPUT INPUT OUTPUT I O 1...

Page 5: ...put signal and RX is the input signal Single fiber models combine input and output signals over one fiber strand Connect fiber cables to the correct TX and RX ports On dual fiber models the TX port of...

Page 6: ...us LED s located on the upper and lower ends of the RJ 45 Socket The upper LED is ON when the input is active and OFF when no input is present The lower LED is ON when the E M output is closed and OFF...

Page 7: ...load wiring prior to installation or maintenance Connect power The system accepts a 24 48VDC or 125VDC local power source depending on the model The power inputs are identified on the top of the devic...

Page 8: ...tatus Description POWER Power ON System Power OK FIBER Fiber Optic Link ON Fiber Link is Connected OFF Fiber Link is Disconnected INPUT Input Sensor ON Input On Active OFF Input Off OUTPUT Output Rela...

Page 9: ...input and output Insertion Loss 0dB 0 5dB each direction Overload Level 8dBm into 600 Ohms E M Input 24 48VDC 3000Vrms optically isolated E M Output 1500VRMS isolation by normally open solid state re...

Page 10: ...20km 12 4 mi 8 9 m A 4D 2EM IO 10 1 B 4D 2EM IO 11 1 60km 37 mi 8 9 m A 4D 2EM IO 14 1 B 4D 2EM IO 15 1 Single mode SC 20km 12 4 mi 8 9 m 4D 2EM IO 40 1 60km 37 mi 8 9 m 4D 2EM IO 41 1 120km 74 mi 8 9...

Reviews: