IMS01N12-E2
3
2. PRODUCT CHECK
Before using this product, check each of the following:
Model code
Check that all of the accessories delivered are complete.
Check that there are no scratch or breakage in external
appearance (case, front panel, or terminal, etc).
X-TIO-R-
-
-
/ Y
(1) (2) (3) (4) (5) (6)
(7) (8) (9)
(1) Type
R: Module for PLC communication
(2) Input channel 1, (3) Input channel 2
K: Thermocouple K
D: RTD Pt100
J: Thermocouple J
P: RTD JPt100
T: Thermocouple T
1: 0 to 10 mV DC
S: Thermocouple S
2: 0 to 100 mV DC
R: Thermocouple R
3: 0 to 1 V DC
A: Thermocouple PL
Ⅱ
4: 0 to 5 V DC
N: Thermocouple N
5: 0 to 10 V DC
E: Thermocouple E
6: 1 to 5 V DC
W: Thermocouple W5Re/W26Re 7: 0 to 20 mA DC
B: Thermocouple B
8: 4 to 20 mA DC
(4) Control output 1, (5) Control output 2
M: Relay contact output
V: Voltage pulse output 0/12 V DC
4: 0 to 5 V DC
5: 0 to 10 V DC
6: 1 to 5 V DC
7: 0 to 20 mA DC
8: 4 to 20 mA DC
(6) CT1 input, (7) CT2 input
N: None
P: CTL-6-P-N
S: CTL-12-S56-10L-N
(8) Communication function (COM. PORT1)
*
1: RS-232C
4: RS-422A
*
Host communication terminals is RS-485 (Fixed),
COM. PORT2/COM. PORT3 is RS-422A (Fixed).
(9) Version symbol
No code: For Japanese domestic market
/Y:
For International market
Heater break alarm (HBA) function cannot be used
when control output is Voltage/Current output.
If any of the products are missing, damaged, or if your
manual is incomplete, please contact RKC sales office
or the agent.
3. PARTS DESCRIPTION
Terminal cover
Indication lamps 1
Address setting
switch 1
Terminal cover
Indication lamps 2
Modular connector
COM. PORT1
Modular connector
COM. PORT2
Modular connector
COM. PORT3
FAIL/RUN
RX/TX
EVENT1
EVENT2
EVENT3
EVENT4
PLC/host communication side Temperature control side
5
4
3
2
1
0
9
8
7
6
5
5
4
3
2
1
0
9
8
7
6
5
FAIL/RUN
RX/TX
EVENT1
EVENT2
EVENT3
EVENT4
[Indication lamps 1]
FAIL/RUN (for temperature control)
When normally:
A green lamp turns on (RUN)
When abnormally:
A red lamp turns on (FAIL)
During self-diagnostic error: A green lamp flashes
RX/TX (for internal communication)
During data send and receive: A green lamp turns on
EVENT 1 to 4
Display various states by setting.
Display contents:
Event 1 state, Event 2 state, Comprehensive event state,
Output state, Control state, Execution segment state, Time
signal state
[Indication lamps 2]
FAIL (for PLC/host communication)
When normally:
A red lamp turns off
When abnormally:
A red lamp turns on
Communication environment setting mode by the switch:
A red lamp flashes
RUN (for PLC/host communication)
When normally:
A green lamp turns on
When abnormally:
A green lamp turns off
Memory backup error:
A green lamp flashes slowly
Module configuration error: A green lamp flashes slowly
PLC communication error: A green lamp flashes slowly
Data collection just after the power is turned on:
A green lamp flashes rapidly
COM. PORT1
During data send and receive: A yellow lamp turns on
COM. PORT2/COM. PORT3
During data send and receive: A yellow lamp turns on
Accessories
End Plate ................................................................... 2
Joint connector cover ................................................. 2
X-TIO-R Instruction Manual (IMS01N12-E2) ............. 1
Indication
lamp 2
Indication
lamp 1
Temperature control side
PLC/host communication side
FAIL
RUN
COM. PROT1
COM. PROT2/COM. PROT3
*