6. Product Information
30
6.2.1 Duty cycle
Adhere to the permissible duty cycle times for the controllers in order to avoid any damage.
You must take note of drive duty cycle in all cases. In some cases, this may be lower. You will find
the stipulated duty cycles on the type plate.
Type/Model
RKMultiControl mono
accu 1.2 Ah
RKMultiControl mono
accu 7 Ah
Dimensions W × H L
110 x 98 x 335
160 x 90 x 250
Rechargeable battery
110 x 62 x 335 Control
Weight
1.5 kg Rechargeable battery
3.5 kg Controllers
approx. 5.6 kg
Rechargeable battery
3.5 kg Controllers
Supply voltage (primary)
230 V (±10 %) 50/60 HZ
115 V (±10 %) 50/60 HZ
Protection category
IP 30
max. current consumption
(primary)
2 A (230 VAC)
4 A (115 VAC)
Duty cycle
S3 10 % at 10 A
S3 15 % at 7 A
S3 10 % at 10 A
S3 15 % at 7 A
Protection class
II
Rated output
250 VA
250 VA
Rechargeable battery current out-
put
max. 5 A
max. 10 A
Nominal voltage rechargeable bat-
tery/type
24 V/Lead-gel
Nominal capacity (20h weighted)
1.2 Ah
7 Ah
Max. charge time of the rechar-
geable battery
approx. 14 hours
Discharge cycles at 30 % discharge
approx. 1000
Length of the rechargeable battery
connecting cable
50 mm
450 mm
Ambient temperature
+5 °C to +40 °C
Relative humidity
30 % to 75 %
Ambient air pressure
700 hPa to 1060 hPa
If you do not observe the duty cycles, you can damage controllers and drives!