MAINTENANCE

The shielded analog output module requires 
little to no maintenance provided that all 
installation instructions are followed. 

CLEANING 

REGULAR CLEANING

Cables must be installed in areas free from oil, 
dirt, grime, and grease.

RJG, Inc. recommends the following cleaners:

• 

Microcare MCC‑CCC Contact Cleaner C

• 

Microcare MCC‑SPR SuprClean™

• 

Miller‑Stephenson MS‑730L Contact Re‑Nu

®

TESTING 

OA1‑M‑V

Test the OA1‑M‑V outputs after assignment 
using the Sensor Locations tool in version 9 
software, or in Machine Setup utilities in version 
10 software.   

WARRANTY

RJG, INC. STANDARD WARRANTY

RJG, Inc. is confident in the quality and 
robustness of the shielded analog output 
module, and so are offering a one‑year 
warranty. RJG’s products are guaranteed against 
defects in material and workmanship for one 
year from the original date of purchase. The 
warranty is void if it is determined that the 
adapter was subjected to abuse or neglect 
beyond the normal wear and tear of field 
use, or in the event the adapter box has been 
opened by the customer.

PRODUCT DISCLAIMER

RJG, Inc. is not responsible for the improper 
installation of this equipment, or any other 
equipment RJG manufactures.

Proper RJG equipment installation does not 
interfere with original equipment safety features 
of the machine. Safety mechanisms on all 
machines should never be removed.

Summary of Contents for Lynx OA1-M-V

Page 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Analog Output Module OA1 M V...

Page 2: ...PRINT DATE 02 25 2019 REVISION NO 0...

Page 3: ...III PRODUCT DESCRIPTION APPLICATIONS 1 PROCESS MONITORING AND CONTROL 1 OPERATION 1 PLASTIC PRESSURE OUTPUT 1 STROKE OUTPUT 1 VELOCITY OUTPUT 1 MACHINE CONTROL FLOW VALVE AND PRESSURE VALVE OUTPUTS 1...

Page 4: ...TY 5 PRODUCT DISCLAIMER 5 TROUBLESHOOTING CUSTOMER SUPPORT 7 RELATED PRODUCTS COMPATIBLE PRODUCTS 9 SHIELDED ANALOG OUTPUT MODULE CABLE C OA1 M 3M 9 LYNX CABLES CE LX5 9 eDART PROCESS CONTROLLER 9 SIM...

Page 5: ...ed uses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or desig...

Page 6: ...Lynx Shielded Analog Output Module OA1 M V Product Manual iv RJG Inc...

Page 7: ...to the machine input card which accepts the signal the C OA1 M 3M is connected to the OA1 M V which collects the signal for use from the eDART In the eDART software the module is configured to enable...

Page 8: ...Lynx Shielded Analog Output Module OA1 M V Product Manual 2 RJG Inc DIMENSIONS CABLE LENGTH The C OA1 M 3M is 9 8 ft 3 m long CABLE LENGTH...

Page 9: ...e machine to an input card on one end and connected to the OR2 M on the other using the four pin connector The shielded analog output module is connected to the ID7 M SEQ or DIN LX D or other shielded...

Page 10: ...ch as the molding machine frame using the supplied 1 38 35 mm DIN rail A clearance height of 6 152 4 mm from the face of the module is recommended NOTE Modules and connecting cables must be located aw...

Page 11: ...10 software WARRANTY RJG INC STANDARD WARRANTY RJG Inc is confident in the quality and robustness of the shielded analog output module and so are offering a one year warranty RJG s products are guara...

Page 12: ...Lynx Shielded Analog Output Module OA1 M V Product Manual 6 RJG Inc...

Page 13: ...ielded Analog Output Module OA1 M V RJG Inc 7 TROUBLESHOOTING CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 8170...

Page 14: ...Lynx Shielded Analog Output Module OA1 M V Product Manual 8 RJG Inc...

Page 15: ...System the C OA1 M 3M provides a connection from molding machines output card and the RJG Inc C OA1 M 3M LYNX CABLES CE LX5 The Lynx sensor cable 2 at right is a polypropylene coated cable suited for...

Page 16: ...DART and any sensor or input that accepts a 0 10 V signal This module is shielded to ensure high quality data even in rugged molding environments LYNX COMMUNICATIONS ADAPTER DIN LX D The Lynx communic...

Page 17: ......

Page 18: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Reviews: