Lynx™ Shielded Analog Output Module OA1‑M‑V | Product Manual
4
RJG, Inc.
INSTALLATION SPECIFICATIONS
The instructions that follow are a general guide;
actual steps necessary to install this product
will vary based on injection molding machine
manufacturer, model, and options.
A clearance height of 6” (152 mm) from the face
of the module(s) is recommended for mounting.
REQUIREMENTS
CAUTION
Before beginning OA1‑M‑V
installation, disconnect and lockout/tag‑out any
and all power to the molding machine. Failure to
comply will result in personal injury or death, and
damage or destruction of equipment.
MOUNTING
Mount the OA1‑M‑V module to a solid
surface—such as the molding machine frame—
using the supplied 1.38” (35 mm) DIN rail. A
clearance height of 6” (152,4 mm) from the face
of the module is recommended.
NOTE
Modules and connecting cables must
be located away from any static sources, such as
feeder tubes and material hoppers.
WIRING
The OA1‑M‑V is interfaced to a machine’s input
card. The C‑OA1‑M‑3M cable has color‑coded
wires to simplify installation. Refer to the table
at right for the correct wire/signal combinations
for installation.
OUTPUT TYPE
SIGNAL
COLOR
0–10 V DC
Positive Signal (+)
Brown
0 V DC
Negative Signal (‑)
Black
No Connection
N/A
Blue
No Connection
N/A
White
CONNECTIONS
Connect the OA1‑M‑V module to the shielded
sequence module ID7‑M‑SEQ—or shielded
communications module DIN/LX‑D—using the
integrated, side‑mount amphenol connector.
Connect the C‑OA1‑M‑V cable to the OA1‑M‑V
module.
Summary of Contents for Lynx OA1-M-V
Page 2: ...PRINT DATE 02 25 2019 REVISION NO 0...
Page 6: ...Lynx Shielded Analog Output Module OA1 M V Product Manual iv RJG Inc...
Page 12: ...Lynx Shielded Analog Output Module OA1 M V Product Manual 6 RJG Inc...
Page 14: ...Lynx Shielded Analog Output Module OA1 M V Product Manual 8 RJG Inc...
Page 17: ......