Lynx™ Embedded Sensors LES‑B‑127‑50/125/500/2000 | Product Manual
30
INSTALLATION SPECIFICATIONS (
continued
)
HIGH‑TEMPERATURE INSTALLATION
The sensor electronics must be kept below 140 °F (60 °C). In order to meet the
temperature conditions for the sensor electronics, a sensor electronics housing can
be mounting on the outside of the mold—provided that there is adequate space on the
mold and clearance for all components. The following depicts such an installation. For
assistance in designing an appropriate installation to prevent heat damage to the sensor
electronics, contact RJG customer support (“Customer Support” on page 54).
LES‑B‑127‑XXXX High Temperature
Sensor Electronics Housing
Sensor Housing
Lid
Sensor
Electronics and
Cables
Retaining
Screws
Sensor Housing
Body
Lynx
Connector
Insulation
Cable Entrance
from Mold
0.020"([0,5 mm)
MIN R. on Sharp
Corners to
Prevent Cable
Wear
LES‑B‑127‑XXXX HIGH TEMPERATURE SENSOR
ELECTRONICS HOUSING RECOMMENDED
DIMENSIONS
Length
Width
Depth
4 Sensors
4.5" (115 mm)
2.6" (65 mm)
1.2" (30 mm)
8 Sensors
4.5" (115 mm)
2.6" (65 mm)
2.2" (55 mm)
Housing Supplied By Customer