Rixen TK-6200 Instruction Manual Download Page 5

 

Key descriptions 

※The ℃/℉ is changeable only under the testing mode.

 

Key  Function 

Descriptions 

LCD display 

 

Power 

On/Off 

Press            once for power on or off. (If the instrument is 

left without any button operation, it will automatically turn 

off after five minutes.) 

 

 

+

 

 

Manual 

turn off 

Hold                key, then hold                key to turn on, 

entering the manual turn off mode. When        appears, 

please let this two keys release. 

 

 
 

 
 

 

 

(2s) 

Baud 
Rate, 

Hi/Lo 

Alarm, 

 

Ref., 

Span 

 

Hold 

mode 

Under testing mode, press              to enter the reading 

HOLD mode. Use                and                to change display 

functions. Press                to leave. 

        HOLD 
AVG        MAX 

          MIN 

Setting 

Mode 

 

Under testing mode, press            for over 2 sec. until the 

area B shows              to enter the setting mode. Push             

key and            key to change the baud rate, after data 

confirmed; please press            for over 2 seconds again. for 

enter the next level. Push            key to increase the value. 

Push            key to reduce the value. Push              key to 

change digit. Determine the value re-hold            key for 

over 2 seconds, into the next level, who wish to skip the 

other settings, hold down            key will be automatically 

set to the last, the complete contents of each set will be 

automatically saved, and return to the testing mode. 

 

 

 
 

Hi.A 

 
 

Lo.A 

 

 

 

(2s) 

Left Key 

Under any mode press            key to change data. 

--

 

Under testing mode, hold            key for over 2 seconds to 

change℃/℉. After changed please let go. 

℃          ℉ 

 

Right Key  Under any mode press                  key to change data. 

--

 

 

 

+

 

Back 

Light on 

Under any mode, press            and            key the back light 

will be turned on. 

Note: 

When the battery power is under 

25%,the LED back light will not be able to function. 

 

Alarm On 

(2s) 

Under any mode, press              and              key after 2 

seconds the buzzer will be turned on. The mark     

appeared. 

 

 

-4- 

 

Summary of Contents for TK-6200

Page 1: ...CONTENTS TK 6200 specifications 1 Instrument descriptions 2 Display descriptions 3 Key descriptions 4 Instructions 5 RS 232 transfer protocol 8 Precautions 11...

Page 2: ...protocol provided Power source 9 V Battery or AC Adapter Dimensions Weight 150 x 75 x 28 mm Approx 320g battery included Input connection Mini connector waterproof socket IP66 Standard Applications TK...

Page 3: ...n LCD Display 7 Battery cover 2 Power switch 8 AC Adaptor Input 3 Setting and switching 9 USB Output port 4 Function key 10 RS 232 Output connector 5 Setting 11 T1 Probe input connector 6 Model No and...

Page 4: ...ay either one testing probe is Abnormal 4 If is appears when turning on the instrument please let go off all keys and tune Instrument on again 3 Display Descriptions Battery Power Symbol Manual shut d...

Page 5: ...e after data confirmed please press for over 2 seconds again for enter the next level Push key to increase the value Push key to reduce the value Push key to change digit Determine the value re hold k...

Page 6: ...emp data Area A T2 Hi A data Area B T2 Lo A data Area C T1 T2 Real time Temperature display T1 T2 Temp data Area A T1 data Area B T2 data Area C Warning alert When the temperature is higher than the H...

Page 7: ...system are changed Condition Display content T1 HOLD display Lock the T1 Temperature data T1 MAX display T1 Maximum Temperature data T1 MIN display T1 Minimum Temperature data T1 AVG display T1 Avera...

Page 8: ...m settings Lowest value 200 0 328 0 Deviation setting range 100 00 Start with 0 00 180 00 Start with 0 00 Span setting range 0 00 200 00 starts with 100 00 7 Display content Description baud display B...

Page 9: ...i Starting address Lo No of Byte Hi No of Byte Hi CRC Lo CRC Hi 02H 03H 00H 00H 00H 04H 44H 3AH Response Data Frame Ex Response value 4 Byte Response Data 80003 Slave address Function Byte count Data...

Page 10: ...te Slave address Function Byte count Data 1 Hi Data 1 Middle Data 1 Lo Data 1 Last 02H 03H 0AH 03H E8H FCH 18H Data 1 Hi and Data 1 Middle is value of T1 Hi A 0x03E8 1000 Data 1 Lo and Data 1 Last is...

Page 11: ...1 T1 Error 1 Power Power Meter is divided into 4 parts 11 100 75 10 74 50 01 49 25 00 24 0 10 Address Data name Data size 0000h T1 Real Time Data Hold 4 Byte 0001h T1 Max 4 Byte 0002h T1 Min 4 Byte 00...

Page 12: ...ed 3 Please keep the temperature stabled when measuring the temperature of an object to obtain a more accurate result 4 When the instrument shows power shortage warning please immediately replace the...

Reviews: