22 | 40
EN
REV | 02
RIV 503
OIL TOPPING UP
The topping up of the oil is necessary when occurs a power loss of the riveting tool or after a long
period of use.
Proceed as per the following instructions:
•
Disconnect the air supply from the tool and keep the tool in a vertical position.
•
Remove oil screw using a 3 mm allen wrench, screw the oil syringe (equipped) until it makes no
resistance, use oil viscosity 32°.
•
Remove the syringe, then screw the oil screw with its o-ring and tighten.
•
Place air without pressing the trigger.
•
Unscrew the screw slowly so that the exceeding oil comes out (bleeding).
• Tighten
screw.
•
The tool is ready.
•
N.B. In case of doubt check stroke, whose regulation should never be lower than the technical data.
N.B. During the operation, wear protective gloves and don't waste oil in the environment. In case of
contact of oil with skin, wash carefully the part with water and soap.
ELIMINATION OF THE TOOL
For the elimination of the tool, make reference to your national laws for safety and evironments care.
Disassemble the tool, dividing its components by materials (aluminium, steel, plastic etc.) then proceed
to scrap in compliance to the current law.
Oil topping up